title: "RAB CEP10S Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/rab-cep10s/
description: "ENERGY STAR specs for RAB CEP10S: 110 CFM, 4.1 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and specs."
---

#  RAB CEP10S Exhaust Fan Specifications

ENERGY STAR PD #4718096 · Bathroom/Utility Room · Qualified 2026-10-07

Verified Specification Summary

In EPA dataset 8dv7-nngq, RAB CEP10S tests at 110 CFM free discharge (100.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 100 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside RAB CEP10S Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 100.8 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.1 CFM/W (#821/1,145)

- **Static Retention**: 91.6% @ 0.25"

- **Motor Draw**: 26.8 W (9.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does RAB CEP10S vs. 1,145-Model ENERGY STAR Benchmarks show?

RAB CEP10S (EPA filing PD #4718096) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.8 CFM out of 110 CFM (91.6% retention, 3.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

RAB maintains 3 active ENERGY STAR blowers; CEP10S (series: Bathroom Exhaust Fans) (PD #4718096) gained qualification on 2026-10-07. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan AER110RGBL (110.0 CFM) and Tech Drive TD-BF-07-plus (110.0 CFM).

## Why avoid unvented attic termination with RAB CEP10S?

Under ASHRAE 62.2 best practice, RAB CEP10S needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern RAB CEP10S?

Before cutting ceiling drywall or sizing attic transitions for RAB CEP10S, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | RAB (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CEP10S / Bathroom Exhaust Fans | PD ID 4718096 (Qualified 2026-10-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit RAB CEP10S?

Bathroom ventilation sizing below maps RAB CEP10S motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for RAB CEP10S

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |

## What peer models sit nearest RAB CEP10S in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to RAB CEP10S.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER110RGBL**](https://siematic-charleston.com/ventilation-fans/broan-aer110rgbl/) | 110 / 97 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-07-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-07-plus/) | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-25L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-25l-5cct-bl/) | 110 / 91.6 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| [**Commercial Electric 7130-16-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-16-ce/) | 110 / 103.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBL**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgbl/) | 110 / 97.6 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |

## What percentage of room demand does RAB CEP10S cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against RAB CEP10S tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does RAB CEP10S fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering RAB CEP10S.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 100.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 100 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for RAB CEP10S?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing RAB CEP10S.

### Is RAB CEP10S code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), RAB CEP10S clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than RAB CEP10S?

Do not force RAB CEP10S into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does RAB CEP10S retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, RAB CEP10S produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will RAB CEP10S disturb adjacent bedrooms during night use?

Acoustic measurement places RAB CEP10S at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running RAB CEP10S continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of RAB CEP10S draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can RAB CEP10S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from RAB CEP10S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing RAB CEP10S?

RAB CEP10S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change RAB CEP10S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing RAB CEP10S's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on RAB CEP10S?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [RAB CEP10SNL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/rab-cep10snl/)
- [RadonAway RP140C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/radonaway-rp140c/)
- [Panasonic RG-Y811SLA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-y811sla-4514159/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)