#  Revent BELH8090110 Exhaust Fan Specifications

ENERGY STAR PD #4718095 · Bathroom/Utility Room · Qualified 2026-10-21

Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent BELH8090110 tests at 110 CFM free discharge (120.6 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 120 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent BELH8090110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 120.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.9 CFM/W (#138/1,145)

- **Static Retention**: 109.6% @ 0.25"

- **Motor Draw**: 10.1 W (3.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent BELH8090110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent BELH8090110 (EPA filing PD #4718095) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 120.6 CFM out of 110 CFM (109.6% retention, 21.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4718095 verifies BELH8090110 (series: ReVent) under Revent (40 listed models, qualified 2026-10-21). Lighting kit: Yes. At 10.9 CFM/W (#138 of 1,145, top 12.1% of 1,145 rated models, more efficient than 87.9% of rated models, 6.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.1 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 88.5 kWh/yr (~$14.16/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Why avoid unvented attic termination with Revent BELH8090110?

Under ASHRAE 62.2 best practice, Revent BELH8090110 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Revent BELH8090110?

Before cutting ceiling drywall or sizing attic transitions for Revent BELH8090110, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BELH8090110 / ReVent | PD ID 4718095 (Qualified 2026-10-21) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (120.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Revent BELH8090110?

Bathroom ventilation sizing below maps Revent BELH8090110 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent BELH8090110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 107 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.7 kWh/yr (~$0.59/yr) | 10.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 88.5 kWh/yr (~$14.16/yr) | 10.1 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Revent BELH8090110 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent BELH8090110.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |

## What percentage of room demand does Revent BELH8090110 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent BELH8090110 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Revent BELH8090110 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Revent BELH8090110 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 120.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 120 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Revent BELH8090110?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent BELH8090110.

### What electrical efficiency and runtime kWh define Revent BELH8090110?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Revent BELH8090110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent BELH8090110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent BELH8090110?

Revent BELH8090110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent BELH8090110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent BELH8090110's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Revent BELH8090110 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Revent BELH8090110 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Revent BELH8090110 undersized or poorly matched for a bath renovation?

Skip Revent BELH8090110 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Revent BELH8090110 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Revent BELH8090110 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Revent BELH8090110 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Revent BELH8090110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## What related resources expand on Revent BELH8090110?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVS80110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvs80110/)
- [Revent RVSC8095110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsc8095110/)
- [QuFresh QUF100X Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/qufresh-quf100x/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)