#  Revent RVL110120130 Exhaust Fan Specifications

ENERGY STAR PD #4587273 · Bathroom/Utility Room · Qualified 2026-04-22

Verified Specification Summary

Tested under HVI protocols, the Revent RVL110120130 exhaust unit achieves 130 CFM at 0.1 in. w.g. (137.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 15.8 CFM/W efficacy, covering standard baths up to 137 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL110120130 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 137.2 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 15.8 CFM/W (#18/1,145)

- **Static Retention**: 105.5% @ 0.25"

- **Motor Draw**: 8.2 W (3.0 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVL110120130 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVL110120130 (EPA filing PD #4587273) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 137.2 CFM out of 130 CFM (105.5% retention, 17.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Revent maintains 40 active ENERGY STAR blowers; RVL110120130 (series: ReVent) (PD #4587273) gained qualification on 2026-04-22. Lighting kit: Yes. At 15.8 CFM/W (#18 of 1,145, top 1.7% of 1,145 rated models, more efficient than 98.3% of rated models, 11.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.2 watts, about 3.0 kWh/yr (~$0.48/yr at $0.16/kWh) for 1 hr/day shower timers or 71.8 kWh/yr (~$11.49/yr) continuously. Closest competing matches include Utilitech UTL110120130 (130.0 CFM) and Utilitech UTS110120130 (130.0 CFM).

## What attic duct routing preserves Revent RVL110120130 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Revent RVL110120130, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Revent RVL110120130 measure up on airflow and noise ratings?

Each row below breaks down Revent RVL110120130 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVL110120130 / ReVent | PD ID 4587273 (Qualified 2026-04-22) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (137.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Revent RVL110120130 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Revent RVL110120130

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 137 sq ft | 1 CFM/sq ft @ 137.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 121 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 87 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.0 kWh/yr (~$0.48/yr) | 8.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 71.8 kWh/yr (~$11.49/yr) | 8.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Revent RVL110120130?

Compare Revent RVL110120130 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTL110120130**](https://siematic-charleston.com/ventilation-fans/utilitech-utl110120130/) | 130 / 137.2 CFM | Unpublished | 15.8 CFM/W | 6 in. diameter |
| [**Utilitech UTS110120130**](https://siematic-charleston.com/ventilation-fans/utilitech-uts110120130/) | 130 / 140.8 CFM | Unpublished | 16.0 CFM/W | 6 in. diameter |
| [**Revent RVS110120130**](https://siematic-charleston.com/ventilation-fans/revent-rvs110120130/) | 130 / 140.8 CFM | Unpublished | 16.0 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3-3442063/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKSL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |

## Can you size Revent RVL110120130 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Revent RVL110120130 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Revent RVL110120130?

Compare where Revent RVL110120130 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 137.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around ENERGY STAR sones up to 137 sq ft
- **Suited to:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Revent RVL110120130?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Revent RVL110120130.

### Is Revent RVL110120130 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Revent RVL110120130 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Revent RVL110120130 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Revent RVL110120130 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL110120130's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVL110120130?

Revent RVL110120130 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVL110120130's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL110120130's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Revent RVL110120130 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Revent RVL110120130 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Revent RVL110120130 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVL110120130 lacks adequate reserve.

### How does Revent RVL110120130 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVL110120130 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

## What neighboring pages and tools support Revent RVL110120130?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Revent RVL110120130.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVS110120130 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvs110120130/)
- [Utilitech UTL110120130 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-utl110120130/)
- [Panasonic FV-13NLFSC1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-13nlfsc1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)