#  Revent RVL150 Exhaust Fan Specifications

ENERGY STAR PD #4653154 · Bathroom/Utility Room · Qualified 2026-05-06

Verified Specification Summary

Certified by EPA ENERGY STAR, Revent RVL150 delivers 150 CFM free-air (152.1 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 12.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 152 sq ft (8-ft height) or 135 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL150 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 152.1 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 12.1 CFM/W (#78/1,145)

- **Static Retention**: 101.4% @ 0.25"

- **Motor Draw**: 12.4 W (4.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVL150 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152.1 CFM out of 150 CFM (101.4% retention, 13.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Revent RVL150 (series: ReVent) under PD #4653154 (40 models registered, 2026-05-06). Lighting kit: Yes. At 12.1 CFM/W (#78 of 1,145, top 6.9% of 1,145 rated models, more efficient than 93.1% of rated models, 7.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.4 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 108.6 kWh/yr (~$17.38/yr) continuously. Closest competing matches include ACIQ AEPD150SC (150.0 CFM) and Revent RVLH150 (150.0 CFM).

## How noisy is Revent RVL150 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Revent RVL150 measures 0.8 sones across the 1,145-model registry.

## Why does rigid 6 in. diameter ducting protect Revent RVL150 airflow?

Connecting Revent RVL150 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Revent RVL150 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVL150 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVL150 / ReVent | PD ID 4653154 (Qualified 2026-05-06) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (152.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Revent RVL150?

Calculated coverage metrics translate Revent RVL150 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Revent RVL150

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 152 sq ft | 1 CFM/sq ft @ 152.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 135 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 102 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 108.6 kWh/yr (~$17.38/yr) | 12.4 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Revent RVL150?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AEPD150SC**](https://siematic-charleston.com/ventilation-fans/aciq-aepd150sc/) | 150 / 130.3 CFM | 0.9 sones (+0.10) | 11.4 CFM/W | 6 in. diameter |
| [**Revent RVLH150**](https://siematic-charleston.com/ventilation-fans/revent-rvlh150/) | 150 / 152.1 CFM | 0.8 sones (Same) | 12.1 CFM/W | 6 in. diameter |
| [**Revent RVS150**](https://siematic-charleston.com/ventilation-fans/revent-rvs150/) | 150 / 155.8 CFM | 0.7 sones (-0.10) | 12.0 CFM/W | 6 in. diameter |
| [**Revent RVSH150**](https://siematic-charleston.com/ventilation-fans/revent-rvsh150/) | 150 / 155.8 CFM | 0.7 sones (-0.10) | 12.0 CFM/W | 6 in. diameter |
| [**Delta 150LED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-150led-adj/) | 150 / 155 CFM | 0.5 sones (-0.30) | 8.8 CFM/W | 6 in. diameter |

## Does Revent RVL150 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVL150 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Revent RVL150?

Compare where Revent RVL150 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 102 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 152.1 CFM net static output
- **Suited to:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Revent RVL150?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVL150.

### Is Revent RVL150 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Revent RVL150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVL150?

Revent RVL150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVL150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL150's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Revent RVL150 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Revent RVL150 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Revent RVL150 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVL150 lacks adequate reserve.

### How does Revent RVL150 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVL150 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Revent RVL150 quiet enough for a primary bedroom bathroom?

At 0.8 sones, Revent RVL150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Where can you explore more benchmarks around Revent RVL150?

Use the related reference pages and estimators below to cross-check Revent RVL150 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVLH150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvlh150/)
- [AUPU B6-13 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13/)
- [HomeWerks Worldwide 7141-50-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50-g4/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)