#  Revent RVM80 Exhaust Fan Specifications

ENERGY STAR PD #2384656 · Bathroom/Utility Room · Qualified 2021-09-24

Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVM80 tests at 80 CFM free discharge (68.2 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 68 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVM80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.2 CFM

- **Noise @ 0.1"**: 0.9 sones (#239/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 85.2% @ 0.25"

- **Motor Draw**: 19.0 W (6.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVM80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.2 CFM out of 80 CFM (85.2% retention, 2.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Revent maintains 40 active ENERGY STAR blowers; RVM80 (series: ReVent) (PD #2384656) gained qualification on 2021-09-24. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.0 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 166.4 kWh/yr (~$26.62/yr) continuously. Closest competing matches include Panasonic FV-08VRE2 (80.0 CFM) and Air King AK80H (80.0 CFM).

## Does Revent RVM80 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVM80 at 0.9 sones.

## Why avoid unvented attic termination with Revent RVM80?

Under ASHRAE 62.2 best practice, Revent RVM80 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Revent RVM80?

Before cutting ceiling drywall or sizing attic transitions for Revent RVM80, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVM80 / ReVent | PD ID 2384656 (Qualified 2021-09-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.9 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Revent RVM80?

Bathroom ventilation sizing below maps Revent RVM80 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVM80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 19.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 166.4 kWh/yr (~$26.62/yr) | 19.0 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Revent RVM80 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVM80.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic FV-08VRE2**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-08vre2/) | 80 / 66.7 CFM | 1.0 sones (+0.10) | 4.3 CFM/W | 4 in. diameter |
| [**Air King AK80H**](https://siematic-charleston.com/ventilation-fans/air-king-ak80h/) | 80 / 71.4 CFM | 1.0 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**Air King AK80LS1**](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/) | 80 / 71.4 CFM | 1.0 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**Air King FR80**](https://siematic-charleston.com/ventilation-fans/air-king-fr80/) | 80 / 71.4 CFM | 1.0 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**Air King FR80H**](https://siematic-charleston.com/ventilation-fans/air-king-fr80h/) | 80 / 71.4 CFM | 1.0 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |

## What percentage of room demand does Revent RVM80 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVM80 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Revent RVM80 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVM80 for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 68.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around 0.9 sones up to 68 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Revent RVM80?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVM80.

### Who should NOT install Revent RVM80 in a bathroom remodel?

Avoid specifying Revent RVM80 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Revent RVM80 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVM80 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Revent RVM80 occupy in EPA filings?

With 0.9 sones at 0.1 in. w.g., Revent RVM80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Revent RVM80 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Revent RVM80 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Revent RVM80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVM80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVM80?

Revent RVM80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVM80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVM80's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Revent RVM80 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVM80 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## What related resources expand on Revent RVM80?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone BE6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-be6/)
- [Broan-Nutone BE6 = BEH with BE6F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-be6-beh-with-be6f/)
- [Loren Cook Company GC-128 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-128/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)