title: "Revent RVP50-ES Bath Fan (50 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/revent-rvp50-es/
description: "ENERGY STAR specs for Revent RVP50-ES: 50 CFM, 2.0 sones (#522 of 607), 7.0 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Revent RVP50-ES Exhaust Fan Specifications

ENERGY STAR PD #3943315 · Bathroom/Utility Room · Qualified 2025-01-24

Verified Specification Summary

Rated for 50 CFM open-air (51.5 CFM at 0.25 in. w.g.), Revent RVP50-ES registers #522 of 607 in quietness (2.0 sones) and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 51 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVP50-ES Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 51.5 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 7.0 CFM/W (#420/1,145)

- **Static Retention**: 103.0% @ 0.25"

- **Motor Draw**: 7.1 W (2.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVP50-ES vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.5 CFM out of 50 CFM (103.0% retention, 15.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3943315 verifies RVP50-ES (series: ReVent) under Revent (40 listed models, qualified 2025-01-24). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.1 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 62.2 kWh/yr (~$9.95/yr) continuously. Closest competing matches include Greenlite G-VENT-9W (50.0 CFM) and Ortech ODDE-50ES (50.0 CFM).

## How does Revent RVP50-ES acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Revent RVP50-ES (2.0 sones).

## How do flex elbows choke Revent RVP50-ES at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Revent RVP50-ES moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Revent RVP50-ES meet residential exhaust fan code specs?

Inspect Revent RVP50-ES mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVP50-ES / ReVent | PD ID 3943315 (Qualified 2025-01-24) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Revent RVP50-ES airflow output?

Annual electricity figures and room square-footage ceilings below reflect Revent RVP50-ES tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Revent RVP50-ES

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 45 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 62.2 kWh/yr (~$9.95/yr) | 7.1 W x 8,760 hrs / 1,000 |

## Which competing models share Revent RVP50-ES airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Greenlite G-VENT-9W**](https://siematic-charleston.com/ventilation-fans/greenlite-g-vent-9w/) | 50 / 39.8 CFM | 2.0 sones (Same) | 7.4 CFM/W | 3 in. diameter |
| [**Ortech ODDE-50ES**](https://siematic-charleston.com/ventilation-fans/ortech-odde-50es/) | 50 / 39.8 CFM | 2.0 sones (Same) | 7.4 CFM/W | 3 in. diameter |
| [**Revent RVG50**](https://siematic-charleston.com/ventilation-fans/revent-rvg50/) | 50 / 51.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| [**Revent RVSX50**](https://siematic-charleston.com/ventilation-fans/revent-rvsx50/) | 50 / 52.2 CFM | 2.0 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| [**Delta SLM70D**](https://siematic-charleston.com/ventilation-fans/delta-slm70d/) | 70 / 56.1 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |

## How much airflow margin does Revent RVP50-ES give your bath?

Run a quick local room-volume check for Revent RVP50-ES by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Revent RVP50-ES suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVP50-ES for your remodel.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 51 sq ft with 8-ft ceilings (45 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Revent RVP50-ES?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVP50-ES.

### What acoustic sone tier does Revent RVP50-ES occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Revent RVP50-ES produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Revent RVP50-ES add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Revent RVP50-ES averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Revent RVP50-ES pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVP50-ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVP50-ES?

Revent RVP50-ES features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVP50-ES's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVP50-ES's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Revent RVP50-ES pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVP50-ES easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Revent RVP50-ES in a bathroom remodel?

Avoid specifying Revent RVP50-ES in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Revent RVP50-ES airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVP50-ES achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

## Which GradeMark tools pair best with Revent RVP50-ES?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Revent RVP50-ES.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVSX50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsx50/)
- [Wintek 7140-50-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-7140-50-ps/)
- [Revent RVG50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvg50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.