---
title: "Revent RVRL5080 Bath Fan (80 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/revent-rvrl5080/
description: "ENERGY STAR specs for Revent RVRL5080: 80 CFM, 8.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Revent RVRL5080 Exhaust Fan Specifications

ENERGY STAR PD #4529280 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVRL5080 tests at 80 CFM free discharge (84.6 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 84 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVRL5080 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 84.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.4 CFM/W (#317/1,145)

- **Static Retention**: 105.7% @ 0.25"

- **Motor Draw**: 9.5 W (3.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVRL5080 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVRL5080 (EPA filing PD #4529280) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 84.6 CFM out of 80 CFM (105.7% retention, 18.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVRL5080 (series: ReVent) under PD #4529280 (40 models registered, 2026-01-28). Lighting kit: Yes. At 8.4 CFM/W (#317 of 1,145, top 27.9% of 1,145 rated models, more efficient than 72.1% of rated models, 3.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.5 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 83.2 kWh/yr (~$13.31/yr) continuously. Closest competing matches include Delta VFB080B4A1-LVDC (80.0 CFM) and Delta 80F-LED (80.0 CFM).

## Why avoid unvented attic termination with Revent RVRL5080?

Under ASHRAE 62.2 best practice, Revent RVRL5080 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Revent RVRL5080?

Before cutting ceiling drywall or sizing attic transitions for Revent RVRL5080, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVRL5080 / ReVent | PD ID 4529280 (Qualified 2026-01-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Revent RVRL5080?

Bathroom ventilation sizing below maps Revent RVRL5080 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVRL5080

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 83.2 kWh/yr (~$13.31/yr) | 9.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Revent RVRL5080 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVRL5080.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VFB080B4A1-LVDC**](https://siematic-charleston.com/ventilation-fans/delta-vfb080b4a1-lvdc/) | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta 80F-LED**](https://siematic-charleston.com/ventilation-fans/delta-80f-led/) | 80 / 61.5 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj/) | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ-BN**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj-bn/) | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ-MB**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj-mb/) | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |

## What percentage of room demand does Revent RVRL5080 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVRL5080 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Revent RVRL5080 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVRL5080.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 84.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 84 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Revent RVRL5080?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVRL5080.

### Which bathroom layouts should pick a larger blower than Revent RVRL5080?

Do not force Revent RVRL5080 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Revent RVRL5080 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Revent RVRL5080 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Revent RVRL5080 disturb adjacent bedrooms during night use?

Acoustic measurement places Revent RVRL5080 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Revent RVRL5080 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Revent RVRL5080 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Revent RVRL5080 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVRL5080's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVRL5080?

Revent RVRL5080 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVRL5080's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVRL5080's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Revent RVRL5080 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVRL5080 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## What related resources expand on Revent RVRL5080?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SLM70D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70d/)
- [Delta SLM70D2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70d2/)
- [PROJECT SOURCE 8768-DS-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/project-source-8768-ds-ps/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
