#  Revent RVS150 Exhaust Fan Specifications

ENERGY STAR PD #4656794 · Bathroom/Utility Room · Qualified 2026-05-06

Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVS150 tests at 150 CFM free discharge (155.8 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 12.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 155 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS150 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 155.8 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 12.0 CFM/W (#80/1,145)

- **Static Retention**: 103.9% @ 0.25"

- **Motor Draw**: 12.5 W (4.6 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVS150 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 155.8 CFM out of 150 CFM (103.9% retention, 16.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Revent's 40-unit lineup, RVS150 (series: ReVent) carries PD #4656794 dating to 2026-05-06. Lighting kit: No. At 12.0 CFM/W (#80 of 1,145, top 7.3% of 1,145 rated models, more efficient than 92.7% of rated models, 7.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.5 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 109.5 kWh/yr (~$17.52/yr) continuously. Closest competing matches include ACIQ AEPD150SC (150.0 CFM) and Revent RVSH150 (150.0 CFM).

## Does Revent RVS150 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVS150 at 0.7 sones.

## Why avoid unvented attic termination with Revent RVS150?

Under ASHRAE 62.2 best practice, Revent RVS150 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Revent RVS150?

Before cutting ceiling drywall or sizing attic transitions for Revent RVS150, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVS150 / ReVent | PD ID 4656794 (Qualified 2026-05-06) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (155.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Revent RVS150?

Bathroom ventilation sizing below maps Revent RVS150 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVS150

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 155 sq ft | 1 CFM/sq ft @ 155.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 138 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 105 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.6 kWh/yr (~$0.74/yr) | 12.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 109.5 kWh/yr (~$17.52/yr) | 12.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Revent RVS150 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVS150.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AEPD150SC**](https://siematic-charleston.com/ventilation-fans/aciq-aepd150sc/) | 150 / 130.3 CFM | 0.9 sones (+0.20) | 11.4 CFM/W | 6 in. diameter |
| [**Revent RVSH150**](https://siematic-charleston.com/ventilation-fans/revent-rvsh150/) | 150 / 155.8 CFM | 0.7 sones (Same) | 12.0 CFM/W | 6 in. diameter |
| [**Revent RVL150**](https://siematic-charleston.com/ventilation-fans/revent-rvl150/) | 150 / 152.1 CFM | 0.8 sones (+0.10) | 12.1 CFM/W | 6 in. diameter |
| [**Revent RVLH150**](https://siematic-charleston.com/ventilation-fans/revent-rvlh150/) | 150 / 152.1 CFM | 0.8 sones (+0.10) | 12.1 CFM/W | 6 in. diameter |
| [**Delta 150LED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-150led-adj/) | 150 / 155 CFM | 0.5 sones (-0.20) | 8.8 CFM/W | 6 in. diameter |

## What percentage of room demand does Revent RVS150 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVS150 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Revent RVS150 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Revent RVS150 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 155.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 0.7 sones up to 155 sq ft
- **Primary match:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Revent RVS150?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVS150.

### What electrical efficiency and runtime kWh define Revent RVS150?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Revent RVS150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVS150?

Revent RVS150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVS150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS150's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Revent RVS150 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Revent RVS150 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Revent RVS150 undersized or poorly matched for a bath renovation?

Skip Revent RVS150 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Revent RVS150 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Revent RVS150 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Revent RVS150 sound output compare to noisy contractor-grade fans?

Rated at 0.7 sones, Revent RVS150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## What related resources expand on Revent RVS150?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVSH150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh150/)
- [Dayton 3DPE5B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe5b/)
- [Air King WM50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-wm50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)