title: "Revent RVS70 Bath Fan (70 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/revent-rvs70/
description: "ENERGY STAR specs for Revent RVS70: 70 CFM, 2.0 sones (#522 of 607), 7.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Revent RVS70 Exhaust Fan Specifications

ENERGY STAR PD #4470613 · Bathroom/Utility Room · Qualified 2025-06-20

Verified Specification Summary

Certified by EPA ENERGY STAR, Revent RVS70 delivers 70 CFM free-air (76 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 7.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 76 sq ft (8-ft height) or 67 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS70 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 76 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 7.8 CFM/W (#365/1,145)

- **Static Retention**: 108.6% @ 0.25"

- **Motor Draw**: 9.0 W (3.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVS70 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 76 CFM out of 70 CFM (108.6% retention, 20.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Revent's 40-unit lineup, RVS70 (series: ReVent) carries PD #4470613 dating to 2025-06-20. Lighting kit: No. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.0 watts, about 3.3 kWh/yr (~$0.53/yr at $0.16/kWh) for 1 hr/day shower timers or 78.8 kWh/yr (~$12.61/yr) continuously. Closest competing matches include Utilitech UTL506070 (70.0 CFM) and Utilitech UTS506070 (70.0 CFM).

## How noisy is Revent RVS70 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Revent RVS70 measures 2.0 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Revent RVS70 airflow?

Connecting Revent RVS70 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Revent RVS70 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVS70 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVS70 / ReVent | PD ID 4470613 (Qualified 2025-06-20) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (76 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Revent RVS70?

Calculated coverage metrics translate Revent RVS70 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Revent RVS70

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 76 sq ft | 1 CFM/sq ft @ 76 CFM |
| Tall Bath (9-ft Ceiling) | Up to 67 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 26 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.3 kWh/yr (~$0.53/yr) | 9.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 78.8 kWh/yr (~$12.61/yr) | 9.0 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Revent RVS70?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTL506070**](https://siematic-charleston.com/ventilation-fans/utilitech-utl506070/) | 70 / 78.6 CFM | Unpublished | 8.1 CFM/W | 4 in. diameter |
| [**Utilitech UTS506070**](https://siematic-charleston.com/ventilation-fans/utilitech-uts506070/) | 70 / 79 CFM | Unpublished | 8.2 CFM/W | 4 in. diameter |
| [**Delta SLM70D**](https://siematic-charleston.com/ventilation-fans/delta-slm70d/) | 70 / 56.1 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| [**Delta SLM70D2**](https://siematic-charleston.com/ventilation-fans/delta-slm70d2/) | 70 / 60.5 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| [**Utilitech 7111-04-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7111-04-l/) | 70 / 56.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |

## Does Revent RVS70 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVS70 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Revent RVS70?

Compare where Revent RVS70 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 26 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 76 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Revent RVS70?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVS70.

### Is Revent RVS70 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Revent RVS70 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVS70?

Revent RVS70 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVS70's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS70's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Revent RVS70 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Revent RVS70 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Revent RVS70 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVS70 lacks adequate reserve.

### How does Revent RVS70 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVS70 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Revent RVS70 quiet enough for a primary bedroom bathroom?

At 2.0 sones, Revent RVS70 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Where can you explore more benchmarks around Revent RVS70?

Use the related reference pages and estimators below to cross-check Revent RVS70 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVSH70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh70/)
- [Tech Drive TD-BF-03-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-03-1/)
- [Revent RVLH70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvlh70/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)