In EPA dataset 8dv7-nngq, Revent RVS80 tests at 80 CFM free discharge (88.8 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 12.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 88 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 88.8 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 12.6 CFM/W (#66/1,145)

- **Static Retention**: 111.0% @ 0.25"

- **Motor Draw**: 6.3 W (2.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVS80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 88.8 CFM out of 80 CFM (111.0% retention, 23.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places RVS80 (series: ReVent) (PD #4517838) among 40 Revent entries qualified through 2025-10-03. Lighting kit: No. At 12.6 CFM/W (#66 of 1,145, top 6.0% of 1,145 rated models, more efficient than 94.0% of rated models, 7.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.3 watts, about 2.3 kWh/yr (~$0.37/yr at $0.16/kWh) for 1 hr/day shower timers or 55.2 kWh/yr (~$8.83/yr) continuously. Closest competing matches include Ortech ODD-90-1 (95.0 CFM) and Revent RVSH80 (80.0 CFM).

## Does Revent RVS80 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVS80 at 0.6 sones.

## Why avoid unvented attic termination with Revent RVS80?

Under ASHRAE 62.2 best practice, Revent RVS80 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Revent RVS80?

Before cutting ceiling drywall or sizing attic transitions for Revent RVS80, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVS80 / ReVent | PD ID 4517838 (Qualified 2025-10-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (88.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Revent RVS80?

Bathroom ventilation sizing below maps Revent RVS80 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVS80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 88 sq ft | 1 CFM/sq ft @ 88.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 78 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 38 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.3 kWh/yr (~$0.37/yr) | 6.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 55.2 kWh/yr (~$8.83/yr) | 6.3 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Revent RVS80 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVS80.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech ODD-90-1**](https://siematic-charleston.com/ventilation-fans/ortech-odd-90-1/) | 95 / 78.9 CFM | 0.7 sones (+0.10) | 13.2 CFM/W | 4 in. diameter |
| [**Revent RVSH80**](https://siematic-charleston.com/ventilation-fans/revent-rvsh80/) | 80 / 88.8 CFM | 0.6 sones (Same) | 12.6 CFM/W | 4 in. diameter |
| [**Broan XB80**](https://siematic-charleston.com/ventilation-fans/broan-xb80/) | 80 / 80 CFM | 0.3 sones (-0.30) | 13.8 CFM/W | 6 in. diameter |
| [**Revent RVL80**](https://siematic-charleston.com/ventilation-fans/revent-rvl80/) | 80 / 89 CFM | 0.8 sones (+0.20) | 12.0 CFM/W | 4 in. diameter |
| [**KORA SBF90DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf90dc-ms/) | 98.1 / N/A CFM | 0.7 sones (+0.10) | 10.7 CFM/W | 4 in. diameter |

## What percentage of room demand does Revent RVS80 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVS80 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Revent RVS80 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Revent RVS80 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 88.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 0.6 sones up to 88 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Revent RVS80?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVS80.

### How does Revent RVS80 sound output compare to noisy contractor-grade fans?

Rated at 0.6 sones, Revent RVS80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Revent RVS80?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Revent RVS80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVS80?

Revent RVS80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVS80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS80's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Revent RVS80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Revent RVS80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Revent RVS80 undersized or poorly matched for a bath renovation?

Skip Revent RVS80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Revent RVS80 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Revent RVS80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## What related resources expand on Revent RVS80?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVSH80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh80/)
- [Ortech ODD-90-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-90-1/)
- [Ortech ODD-70-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-70-1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)