title: "Revent RVSSC80100 Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/revent-rvssc80100/
description: "ENERGY STAR specs for Revent RVSSC80100: 100 CFM, 9.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Revent RVSSC80100 Exhaust Fan Specifications

ENERGY STAR PD #4519562 · Bathroom/Utility Room · Qualified 2025-12-19

Verified Specification Summary

Certified by EPA ENERGY STAR, Revent RVSSC80100 delivers 100 CFM free-air (107.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 107 sq ft (8-ft height) or 95 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSSC80100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 107.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.4 CFM/W (#254/1,145)

- **Static Retention**: 107.3% @ 0.25"

- **Motor Draw**: 10.6 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVSSC80100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVSSC80100 (EPA filing PD #4519562) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.3 CFM out of 100 CFM (107.3% retention, 19.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVSSC80100 (series: ReVent) under PD #4519562 (40 models registered, 2025-12-19). Lighting kit: No. At 9.4 CFM/W (#254 of 1,145, top 22.4% of 1,145 rated models, more efficient than 77.6% of rated models, 4.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect Revent RVSSC80100 airflow?

Connecting Revent RVSSC80100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Revent RVSSC80100 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVSSC80100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVSSC80100 / ReVent | PD ID 4519562 (Qualified 2025-12-19) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (107.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Revent RVSSC80100?

Calculated coverage metrics translate Revent RVSSC80100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Revent RVSSC80100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 107 sq ft | 1 CFM/sq ft @ 107.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 57 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Revent RVSSC80100?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Revent RVSSC80100 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVSSC80100 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Revent RVSSC80100?

Match Revent RVSSC80100 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 57 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 107.3 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Revent RVSSC80100?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVSSC80100.

### What happens to Revent RVSSC80100 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Revent RVSSC80100 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Revent RVSSC80100 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Revent RVSSC80100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Revent RVSSC80100 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Revent RVSSC80100 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Revent RVSSC80100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSSC80100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVSSC80100?

Revent RVSSC80100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVSSC80100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSSC80100's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Revent RVSSC80100 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Revent RVSSC80100 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Revent RVSSC80100 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Revent RVSSC80100.

## Where can you explore more benchmarks around Revent RVSSC80100?

Use the related reference pages and estimators below to cross-check Revent RVSSC80100 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PCLPD100XHP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pclpd100xhp/)
- [S&P TD-100X1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-100x1/)
- [Revent RVSSC5080100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvssc5080100/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)