#  Revent RVSX50 Exhaust Fan Specifications

ENERGY STAR PD #4497569 · Bathroom/Utility Room · Qualified 2025-08-08

Verified Specification Summary

Tested under HVI protocols, the Revent RVSX50 exhaust unit achieves 50 CFM at 0.1 in. w.g. (51.2 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 7.3 CFM/W efficacy, covering standard baths up to 51 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSX50 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 51.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 7.3 CFM/W (#400/1,145)

- **Static Retention**: 102.4% @ 0.25"

- **Motor Draw**: 6.8 W (2.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Revent RVSX50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.2 CFM out of 50 CFM (102.4% retention, 14.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places RVSX50 (series: ReVent) (PD #4497569) among 40 Revent entries qualified through 2025-08-08. Lighting kit: No. At 7.3 CFM/W (#400 of 1,145, top 35.5% of 1,145 rated models, more efficient than 64.5% of rated models, 2.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Revent RVL50 (50.0 CFM).

## Where do Revent RVSX50 sones rank across EPA ENERGY STAR fans?

Comparing Revent RVSX50 (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Revent RVSX50 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Revent RVSX50, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Revent RVSX50 measure up on airflow and noise ratings?

Each row below breaks down Revent RVSX50 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Revent (40 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RVSX50 / ReVent | PD ID 4497569 (Qualified 2025-08-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Revent RVSX50 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Revent RVSX50

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 45 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.5 kWh/yr (~$0.40/yr) | 6.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 59.6 kWh/yr (~$9.54/yr) | 6.8 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Revent RVSX50?

Compare Revent RVSX50 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| [**Revent RVL50**](https://siematic-charleston.com/ventilation-fans/revent-rvl50/) | 50 / 47 CFM | 1.1 sones (-0.40) | 7.6 CFM/W | 4 in. diameter |
| [**Revent RVLH50**](https://siematic-charleston.com/ventilation-fans/revent-rvlh50/) | 50 / 47 CFM | 1.1 sones (-0.40) | 7.6 CFM/W | 4 in. diameter |
| [**Greenlite G-VENT-9W**](https://siematic-charleston.com/ventilation-fans/greenlite-g-vent-9w/) | 50 / 39.8 CFM | 2.0 sones (+0.50) | 7.4 CFM/W | 3 in. diameter |
| [**Ortech ODDE-50ES**](https://siematic-charleston.com/ventilation-fans/ortech-odde-50es/) | 50 / 39.8 CFM | 2.0 sones (+0.50) | 7.4 CFM/W | 3 in. diameter |

## Can you size Revent RVSX50 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Revent RVSX50 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Revent RVSX50 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Revent RVSX50 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 51.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.5 sones up to 51 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Revent RVSX50?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Revent RVSX50.

### Will long attic ducting choke Revent RVSX50 capacity?

Because static drag at 0.25 in. w.g. lowers Revent RVSX50 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Revent RVSX50 compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Revent RVSX50 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Revent RVSX50 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Revent RVSX50 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Revent RVSX50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSX50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Revent RVSX50?

Revent RVSX50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Revent RVSX50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSX50's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Revent RVSX50 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Revent RVSX50 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Revent RVSX50?

Rule out Revent RVSX50 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What neighboring pages and tools support Revent RVSX50?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Revent RVSX50.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KORA SBF110N Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/)
- [Air King AK90 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak90/)
- [Utilitech 7142-70-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)