Verified Specification Summary

Tested under HVI protocols, the S&P PC110XP exhaust unit achieves 120 CFM at 0.1 in. w.g. (94.2 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 94 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC110XP Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 120 / 94.2 CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 78.5% @ 0.25"

- **Motor Draw**: 28.6 W (10.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PC110XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 120 CFM open-air to 94.2 CFM at 0.25 in. w.g. (78.5% retention, 9.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

S&P maintains 29 active ENERGY STAR blowers; PC110XP (series: PC) (PD #2402470) gained qualification on 2022-09-16. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.6 watts, about 10.4 kWh/yr (~$1.66/yr at $0.16/kWh) for 1 hr/day shower timers or 250.5 kWh/yr (~$40.08/yr) continuously. Closest competing matches include Kaze Appliance SEP120 (120.0 CFM) and Broan QTXEG110 (110.0 CFM).

## Where do S&P PC110XP sones rank across EPA ENERGY STAR fans?

Comparing S&P PC110XP (0.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves S&P PC110XP CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on S&P PC110XP, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does S&P PC110XP measure up on airflow and noise ratings?

Each row below breaks down S&P PC110XP certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PC110XP / PC | PD ID 2402470 (Qualified 2022-09-16) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (94.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect S&P PC110XP CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for S&P PC110XP

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.4 kWh/yr (~$1.66/yr) | 28.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 250.5 kWh/yr (~$40.08/yr) | 28.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against S&P PC110XP?

Compare S&P PC110XP side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Kaze Appliance SEP120**](https://siematic-charleston.com/ventilation-fans/kaze-appliance-sep120/) | 120 / 94.2 CFM | 0.3 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**Broan QTXEG110**](https://siematic-charleston.com/ventilation-fans/broan-qtxeg110/) | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| [**Broan QTXEG110 = QTXEGH with QTXEG110F**](https://siematic-charleston.com/ventilation-fans/broan-qtxeg110-qtxegh-with-qtxeg110f/) | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| [**Broan QTXEG110S**](https://siematic-charleston.com/ventilation-fans/broan-qtxeg110s/) | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| [**Broan QTXEG110S = QTXEGSH with QTXEG110SF**](https://siematic-charleston.com/ventilation-fans/broan-qtxeg110s-qtxegsh-with-qtxeg110sf/) | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |

## Can you size S&P PC110XP for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P PC110XP verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out S&P PC110XP?

Compare where S&P PC110XP excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 94.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 0.3 sones up to 94 sq ft
- **Suited to:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to S&P PC110XP?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P PC110XP.

### How does S&P PC110XP handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., S&P PC110XP yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is S&P PC110XP quiet enough for a primary bedroom bathroom?

At 0.3 sones, S&P PC110XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is S&P PC110XP energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can S&P PC110XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC110XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PC110XP?

S&P PC110XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PC110XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC110XP's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can S&P PC110XP serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: S&P PC110XP supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap S&P PC110XP for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, S&P PC110XP lacks adequate reserve.

## What neighboring pages and tools support S&P PC110XP?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around S&P PC110XP.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan (Canada) XB110L1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-canada-xb110l1/)
- [Broan XB110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-xb110/)
- [Kaze Appliance SEP120 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kaze-appliance-sep120/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)