#  S&P PC150XP Exhaust Fan Specifications

ENERGY STAR PD #2402468 · Bathroom/Utility Room · Qualified 2022-09-16

Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P PC150XP tests at 150 CFM free discharge (123.8 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 123 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC150XP Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 123.8 CFM

- **Noise @ 0.1"**: 0.5 sones (#83/607)

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 82.5% @ 0.25"

- **Motor Draw**: 32.6 W (11.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PC150XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places PC150XP (series: PC) (PD #2402468) among 29 S&P entries qualified through 2022-09-16. Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Anzzi EF-AZ104WH (150.0 CFM).

## Does S&P PC150XP fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PC150XP at 0.5 sones.

## Why avoid unvented attic termination with S&P PC150XP?

Under ASHRAE 62.2 best practice, S&P PC150XP needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern S&P PC150XP?

Before cutting ceiling drywall or sizing attic transitions for S&P PC150XP, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PC150XP / PC | PD ID 2402468 (Qualified 2022-09-16) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit S&P PC150XP?

Bathroom ventilation sizing below maps S&P PC150XP motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P PC150XP

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |

## What peer models sit nearest S&P PC150XP in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PC150XP.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AEP150**](https://siematic-charleston.com/ventilation-fans/aciq-aep150/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Anzzi EF-AZ104WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az104wh/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Anzzi EF-AZ105WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az105wh/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Cyclone ESCBP150**](https://siematic-charleston.com/ventilation-fans/cyclone-escbp150/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Kaze Appliance SEP150**](https://siematic-charleston.com/ventilation-fans/kaze-appliance-sep150/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |

## What percentage of room demand does S&P PC150XP cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PC150XP tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip S&P PC150XP on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P PC150XP carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 123.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 0.5 sones up to 123 sq ft
- **Works well for:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for S&P PC150XP?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PC150XP.

### How loud is S&P PC150XP compared with a standard 3.0 sone builder fan?

Tested at 0.5 sones, S&P PC150XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does S&P PC150XP consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, S&P PC150XP draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can S&P PC150XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC150XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PC150XP?

S&P PC150XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PC150XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC150XP's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does S&P PC150XP score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P PC150XP delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify S&P PC150XP?

Rule out S&P PC150XP when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke S&P PC150XP capacity?

Because static drag at 0.25 in. w.g. lowers S&P PC150XP from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

## What related resources expand on S&P PC150XP?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Dayton 5AE70B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-5ae70b/)
- [Panasonic Eco Solutions RG-E110THA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-e110tha/)
- [Ortech OD-1505PB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-od-1505pb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)