Certified by EPA ENERGY STAR, S&P PC80XP delivers 90 CFM free-air (70.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 70 sq ft (8-ft height) or 63 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC80XP Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 70.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 78.8% @ 0.25"

- **Motor Draw**: 21.4 W (7.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PC80XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 70.9 CFM at 0.25 in. w.g. (78.8% retention, 8.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

S&P maintains 29 active ENERGY STAR blowers; PC80XP (series: PC) (PD #3626825) gained qualification on 2024-08-30. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech OD-9005PB (90.0 CFM) and Dayton 5AE68B (90.0 CFM).

## How noisy is S&P PC80XP compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while S&P PC80XP measures 0.7 sones across the 1,145-model registry.

## Why does rigid 6 in. diameter ducting protect S&P PC80XP airflow?

Connecting S&P PC80XP through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify S&P PC80XP performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for S&P PC80XP lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PC80XP / PC | PD ID 3626825 (Qualified 2024-08-30) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (70.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit S&P PC80XP?

Calculated coverage metrics translate S&P PC80XP airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for S&P PC80XP

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to S&P PC80XP?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech OD-9005PB**](https://siematic-charleston.com/ventilation-fans/ortech-od-9005pb/) | 90 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-11-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/) | 90 / 79.5 CFM | 0.8 sones (+0.10) | 4.4 CFM/W | 4 in. diameter |
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (+0.10) | 4.5 CFM/W | 6 in. diameter |

## Does S&P PC80XP match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check S&P PC80XP percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip S&P PC80XP on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P PC80XP carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 70.9 CFM net static output
- **Works well for:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for S&P PC80XP?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around S&P PC80XP.

### How loud is S&P PC80XP compared with a standard 3.0 sone builder fan?

Tested at 0.7 sones, S&P PC80XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does S&P PC80XP consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, S&P PC80XP draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can S&P PC80XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC80XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PC80XP?

S&P PC80XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PC80XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC80XP's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does S&P PC80XP score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P PC80XP delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify S&P PC80XP?

Rule out S&P PC80XP when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke S&P PC80XP capacity?

Because static drag at 0.25 in. w.g. lowers S&P PC80XP from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

## Where can you explore more benchmarks around S&P PC80XP?

Use the related reference pages and estimators below to cross-check S&P PC80XP against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [ACIQ AEP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aep80/)
- [ACIQ AES80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aes80/)
- [Ortech OD-9005PB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-od-9005pb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)