title: "SandP PCLP100 Bath Fan (100 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-pclp100/
description: "ENERGY STAR specs for SandP PCLP100: 100 CFM, 2.0 sones (#522 of 607), 4.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  S&P PCLP100 Exhaust Fan Specifications

ENERGY STAR PD #2382308 · Bathroom/Utility Room · Qualified 2021-07-16

Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P PCLP100 tests at 100 CFM free discharge (90.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 90 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 90.2 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 90.2% @ 0.25"

- **Motor Draw**: 23.8 W (8.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PCLP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2382308 verifies PCLP100 (series: PCLP) under S&P (29 listed models, qualified 2021-07-16). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.8 watts, about 8.7 kWh/yr (~$1.39/yr at $0.16/kWh) for 1 hr/day shower timers or 208.5 kWh/yr (~$33.36/yr) continuously. Closest competing matches include Broan L100EL (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).

## Does S&P PCLP100 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PCLP100 at 2.0 sones.

## Why avoid unvented attic termination with S&P PCLP100?

Under ASHRAE 62.2 best practice, S&P PCLP100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern S&P PCLP100?

Before cutting ceiling drywall or sizing attic transitions for S&P PCLP100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCLP100 / PCLP | PD ID 2382308 (Qualified 2021-07-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (90.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit S&P PCLP100?

Bathroom ventilation sizing below maps S&P PCLP100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P PCLP100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.7 kWh/yr (~$1.39/yr) | 23.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 208.5 kWh/yr (~$33.36/yr) | 23.8 W x 8,760 hrs / 1,000 |

## What peer models sit nearest S&P PCLP100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PCLP100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan L100EL**](https://siematic-charleston.com/ventilation-fans/broan-l100el/) | 100 / N/A CFM | Unpublished | 4.3 CFM/W | 8 in. diameter |
| [**Panasonic FV-0811RF1**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rf1-2390260/) | 100 / 103.6 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |
| [**ACIQ AP100**](https://siematic-charleston.com/ventilation-fans/aciq-ap100/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Air King FR100**](https://siematic-charleston.com/ventilation-fans/air-king-fr100/) | 100 / 82.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ107WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az107wh/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## What percentage of room demand does S&P PCLP100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PCLP100 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install S&P PCLP100 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P PCLP100 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 90.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 2.0 sones up to 90 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for S&P PCLP100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PCLP100.

### Why check S&P PCLP100 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P PCLP100 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does S&P PCLP100 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, S&P PCLP100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define S&P PCLP100?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can S&P PCLP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PCLP100?

S&P PCLP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PCLP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP100's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does S&P PCLP100 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P PCLP100 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is S&P PCLP100 undersized or poorly matched for a bath renovation?

Skip S&P PCLP100 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What related resources expand on S&P PCLP100?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone BENL8 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-benl8/)
- [Air King BFQ75 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfq75/)
- [HomeWerks Worldwide 7105-12-MB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-12-mb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)