title: "SandP PCLP100XP Bath Fan (100 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-pclp100xp/
description: "ENERGY STAR specs for SandP PCLP100XP: 100 CFM, 1.5 sones (#412 of 607), 4.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  S&P PCLP100XP Exhaust Fan Specifications

ENERGY STAR PD #2382307 · Bathroom/Utility Room · Qualified 2021-07-16

Verified Specification Summary

The S&P PCLP100XP (PCLP) moves 100 CFM at 0.1 in. w.g. (90.2 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 90 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP100XP Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 90.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 90.2% @ 0.25"

- **Motor Draw**: 23.8 W (8.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PCLP100XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside S&P's 29-unit lineup, PCLP100XP (series: PCLP) carries PD #2382307 dating to 2021-07-16. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.8 watts, about 8.7 kWh/yr (~$1.39/yr at $0.16/kWh) for 1 hr/day shower timers or 208.5 kWh/yr (~$33.36/yr) continuously. Closest competing matches include ACIQ AES100 (100.0 CFM) and CFM TF100N (100.0 CFM).

## Where does S&P PCLP100XP sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

## How does duct geometry alter S&P PCLP100XP static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to S&P PCLP100XP?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P PCLP100XP alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCLP100XP / PCLP | PD ID 2382307 (Qualified 2021-07-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (90.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can S&P PCLP100XP ventilate safely?

Sizing outputs below convert S&P PCLP100XP tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for S&P PCLP100XP

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.7 kWh/yr (~$1.39/yr) | 23.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 208.5 kWh/yr (~$33.36/yr) | 23.8 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match S&P PCLP100XP closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AES100**](https://siematic-charleston.com/ventilation-fans/aciq-aes100/) | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**CFM TF100N**](https://siematic-charleston.com/ventilation-fans/cfm-tf100n/) | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ106MB**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106mb/) | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ106WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106wh/) | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL100 (484302)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl100-484302/) | 100 / 91.2 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |

## Will S&P PCLP100XP clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether S&P PCLP100XP satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does S&P PCLP100XP suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying S&P PCLP100XP for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 40 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 90 sq ft with 8-ft ceilings (80 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern S&P PCLP100XP?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P PCLP100XP.

### Does S&P PCLP100XP pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), S&P PCLP100XP easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install S&P PCLP100XP in a bathroom remodel?

Avoid specifying S&P PCLP100XP in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut S&P PCLP100XP airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, S&P PCLP100XP achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does S&P PCLP100XP occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., S&P PCLP100XP produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does S&P PCLP100XP add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, S&P PCLP100XP averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can S&P PCLP100XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP100XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PCLP100XP?

S&P PCLP100XP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PCLP100XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP100XP's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to S&P PCLP100XP?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for S&P PCLP100XP.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech 7115-01 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/)
- [Utilitech 7115-02 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/)
- [Hunter 90065A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/hunter-90065a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)