title: "SandP PCLP80 Bath Fan (80 CFM, 1.2 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-pclp80/
description: "ENERGY STAR specs for SandP PCLP80: 80 CFM, 1.2 sones (#380 of 607), 4.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  S&P PCLP80 Exhaust Fan Specifications

ENERGY STAR PD #2382099 · Bathroom/Utility Room · Qualified 2021-06-25

Verified Specification Summary

Homeowners specifying S&P PCLP80 gain 80 CFM at 0.1 in. w.g. (68.3 CFM at 0.25 in. w.g.) where it registers #380 of 607 in quietness (1.2 sones) and delivers 4.7 CFM/W efficacy, venting bathrooms up to 68 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.3 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 4.7 CFM/W (#545/1,145)

- **Static Retention**: 85.4% @ 0.25"

- **Motor Draw**: 17.0 W (6.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PCLP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms S&P PCLP80 (series: PCLP) under PD #2382099 (29 models registered, 2021-06-25). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include Fantech RCS80L (80.0 CFM) and HomeWerks Worldwide 7117-01-BN (80.0 CFM).

## What acoustic percentile does S&P PCLP80 occupy among 1,145 bath blowers?

Inspect how S&P PCLP80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits S&P PCLP80 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around S&P PCLP80 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do S&P PCLP80 acoustic and static metrics stand?

Compare S&P PCLP80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCLP80 / PCLP | PD ID 2382099 (Qualified 2021-06-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can S&P PCLP80 handle taller ceilings or walk-in tub steam?

Evaluate how S&P PCLP80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for S&P PCLP80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.9 kWh/yr (~$23.82/yr) | 17.0 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near S&P PCLP80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Fantech RCS80L**](https://siematic-charleston.com/ventilation-fans/fantech-rcs80l/) | 80 / 80.4 CFM | 1.2 sones (Same) | 5.1 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7117-01-BN**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7117-01-bn/) | 80 / 65.4 CFM | 1.1 sones (-0.10) | 4.6 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7117-01-WH**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7117-01-wh/) | 80 / 65.4 CFM | 1.1 sones (-0.10) | 4.6 CFM/W | 4 in. diameter |
| [**Fantech SMPL80 (484300)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl80-484300/) | 80 / 75 CFM | 1.1 sones (-0.10) | 5.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL80L (484301)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl80l-484301/) | 80 / 75 CFM | 1.1 sones (-0.10) | 5.0 CFM/W | 4 in. diameter |

## Is S&P PCLP80 sized right for your shower or tub room?

Check whether S&P PCLP80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying S&P PCLP80?

Match S&P PCLP80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 68.3 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for S&P PCLP80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to S&P PCLP80.

### Where does S&P PCLP80 sit on acoustic comfort for senior homeowners?

Measuring 1.2 sones, S&P PCLP80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does S&P PCLP80 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running S&P PCLP80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can S&P PCLP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PCLP80?

S&P PCLP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PCLP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP80's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can S&P PCLP80 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), S&P PCLP80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does S&P PCLP80 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with S&P PCLP80.

### What happens to S&P PCLP80 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, S&P PCLP80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## How can you cross-check S&P PCLP80 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for S&P PCLP80.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-17 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-17/)
- [VENTECHLATION BPT13-12EN-T Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en-t/)
- [Fantech RCS80L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-rcs80l/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)