title: "SandP PCLPD100XHP Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-pclpd100xhp/
description: "ENERGY STAR specs for SandP PCLPD100XHP: 100 CFM, 9.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  S&P PCLPD100XHP Exhaust Fan Specifications

ENERGY STAR PD #2406410 · Bathroom/Utility Room · Qualified 2022-12-16

Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P PCLPD100XHP tests at 100 CFM free discharge (106.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 106 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLPD100XHP Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.3 CFM/W (#258/1,145)

- **Static Retention**: 106.5% @ 0.25"

- **Motor Draw**: 10.8 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P PCLPD100XHP vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P PCLPD100XHP (EPA filing PD #2406410) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms S&P PCLPD100XHP (series: PCLPD) under PD #2406410 (29 models registered, 2022-12-16). Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## Why avoid unvented attic termination with S&P PCLPD100XHP?

Under ASHRAE 62.2 best practice, S&P PCLPD100XHP needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern S&P PCLPD100XHP?

Before cutting ceiling drywall or sizing attic transitions for S&P PCLPD100XHP, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCLPD100XHP / PCLPD | PD ID 2406410 (Qualified 2022-12-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit S&P PCLPD100XHP?

Bathroom ventilation sizing below maps S&P PCLPD100XHP motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P PCLPD100XHP

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |

## What peer models sit nearest S&P PCLPD100XHP in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PCLPD100XHP.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## What percentage of room demand does S&P PCLPD100XHP cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PCLPD100XHP tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying S&P PCLPD100XHP?

Match S&P PCLPD100XHP directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 106 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for S&P PCLPD100XHP?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PCLPD100XHP.

### Where does S&P PCLPD100XHP sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, S&P PCLPD100XHP produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does S&P PCLPD100XHP cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running S&P PCLPD100XHP 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can S&P PCLPD100XHP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLPD100XHP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P PCLPD100XHP?

S&P PCLPD100XHP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P PCLPD100XHP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLPD100XHP's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can S&P PCLPD100XHP ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), S&P PCLPD100XHP covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does S&P PCLPD100XHP run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with S&P PCLPD100XHP.

### What happens to S&P PCLPD100XHP CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, S&P PCLPD100XHP moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## What related resources expand on S&P PCLPD100XHP?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P TD-100X1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-100x1/)
- [Spruce RB110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/spruce-rb110/)
- [Revent RVSSC80100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvssc80100/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)