title: "SandP RF8-120EC-ES24V Bath Fan (130 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-rf8-120ec-es24v/
description: "ENERGY STAR specs for SandP RF8-120EC-ES24V: 130 CFM, 4.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  S&P RF8-120EC-ES24V Exhaust Fan Specifications

ENERGY STAR PD #2343142 · In-line (single-port) · Qualified 2018-04-27

Verified Specification Summary

The S&P RF8-120EC-ES24V (Refresh) moves 130 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.9 CFM/W efficacy, sizing bathrooms up to 130 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P RF8-120EC-ES24V Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 26.5 W (9.7 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P RF8-120EC-ES24V vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P RF8-120EC-ES24V (EPA filing PD #2343142) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: S&P registers 29 certified models, with SKU RF8-120EC-ES24V (series: Refresh) (PD #2343142) certified since 2018-04-27. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.5 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 232.1 kWh/yr (~$37.14/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

## How does duct geometry alter S&P RF8-120EC-ES24V static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to S&P RF8-120EC-ES24V?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P RF8-120EC-ES24V alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RF8-120EC-ES24V / Refresh | PD ID 2343142 (Qualified 2018-04-27) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (130 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can S&P RF8-120EC-ES24V ventilate safely?

Sizing outputs below convert S&P RF8-120EC-ES24V tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for S&P RF8-120EC-ES24V

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 232.1 kWh/yr (~$37.14/yr) | 26.5 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match S&P RF8-120EC-ES24V closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |

## Will S&P RF8-120EC-ES24V clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether S&P RF8-120EC-ES24V satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does S&P RF8-120EC-ES24V suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying S&P RF8-120EC-ES24V for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 80 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 130 sq ft with 8-ft ceilings (115 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern S&P RF8-120EC-ES24V?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P RF8-120EC-ES24V.

### What acoustic sone tier does S&P RF8-120EC-ES24V occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., S&P RF8-120EC-ES24V produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does S&P RF8-120EC-ES24V add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, S&P RF8-120EC-ES24V averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can S&P RF8-120EC-ES24V pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P RF8-120EC-ES24V's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P RF8-120EC-ES24V?

S&P RF8-120EC-ES24V features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P RF8-120EC-ES24V's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P RF8-120EC-ES24V's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does S&P RF8-120EC-ES24V pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), S&P RF8-120EC-ES24V easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install S&P RF8-120EC-ES24V in a bathroom remodel?

Avoid specifying S&P RF8-120EC-ES24V in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut S&P RF8-120EC-ES24V airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, S&P RF8-120EC-ES24V achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

## Which guides and calculators connect next to S&P RF8-120EC-ES24V?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for S&P RF8-120EC-ES24V.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Whirlpool Corporation WVU7130JS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/whirlpool-corporation-wvu7130js/)
- [Aprilaire 8144NC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aprilaire-8144nc/)
- [S&P RF8-120EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-rf8-120ec/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)