title: "SandP TD-150 Bath Fan (260 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/s-p-td-150/
description: "ENERGY STAR specs for SandP TD-150: 260 CFM, 4.3 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  S&P TD-150 Exhaust Fan Specifications

ENERGY STAR PD #2395001 · In-line (single-port) · Qualified 2022-04-22

Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P TD-150 tests at 260 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 260 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-150 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 260 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 60.5 W (22.1 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does S&P TD-150 vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P TD-150 (EPA filing PD #2395001) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

S&P maintains 29 active ENERGY STAR blowers; TD-150 (series: TD Mixvent) (PD #2395001) gained qualification on 2022-04-22. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 60.5 watts, about 22.1 kWh/yr (~$3.54/yr at $0.16/kWh) for 1 hr/day shower timers or 530.0 kWh/yr (~$84.80/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

## Why avoid unvented attic termination with S&P TD-150?

Under ASHRAE 62.2 best practice, S&P TD-150 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern S&P TD-150?

Before cutting ceiling drywall or sizing attic transitions for S&P TD-150, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | S&P (29 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-150 / TD Mixvent | PD ID 2395001 (Qualified 2022-04-22) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit S&P TD-150?

Bathroom ventilation sizing below maps S&P TD-150 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P TD-150

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 22.1 kWh/yr (~$3.54/yr) | 60.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 530.0 kWh/yr (~$84.80/yr) | 60.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest S&P TD-150 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P TD-150.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE72A**](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/) | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Greenheck SP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a200/) | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Fantech FG 6 (40406)**](https://siematic-charleston.com/ventilation-fans/fantech-fg-6-40406/) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |
| [**Fantech FGC 6 (40381)**](https://siematic-charleston.com/ventilation-fans/fantech-fgc-6-40381/) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |
| [**Fantech PB 270-2 (40572)**](https://siematic-charleston.com/ventilation-fans/fantech-pb-270-2-40572/) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |

## What percentage of room demand does S&P TD-150 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P TD-150 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip S&P TD-150 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P TD-150 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 260 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 260 sq ft
- **Works well for:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for S&P TD-150?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P TD-150.

### How much power does S&P TD-150 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, S&P TD-150 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can S&P TD-150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing S&P TD-150?

S&P TD-150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change S&P TD-150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-150's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does S&P TD-150 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P TD-150 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify S&P TD-150?

Rule out S&P TD-150 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke S&P TD-150 capacity?

Because static drag at 0.25 in. w.g. lowers S&P TD-150 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is S&P TD-150 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, S&P TD-150 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

## What related resources expand on S&P TD-150?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan L200E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l200e/)
- [Broan L250EL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l250el/)
- [Fantech PB 270L7V-2 (44946) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb-270l7v-2-44946/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)