title: "Systemair K 5 (40404) Bath Fan (120 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/systemair-k-5-40404/
description: "ENERGY STAR specs for Systemair K 5 (40404): 120 CFM, 7.0 CFM/W, 5 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Systemair K 5 (40404) Exhaust Fan Specifications

ENERGY STAR PD #4577053 · In-line (single-port) · Qualified 2026-03-25

Verified Specification Summary

Rated for 120 CFM open-air (unpublished 0.25 in. w.g. output), Systemair K 5 (40404) omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 120 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Systemair K 5 (40404) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 120 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.0 CFM/W (#420/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 17.1 W (6.2 kWh/yr)

- **Duct & Tier**: 5 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Systemair K 5 (40404) vs. 1,145-Model ENERGY STAR Benchmarks show?

Systemair K 5 (40404) (EPA filing PD #4577053) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4577053 verifies K 5 (40404) (series: K Series) under Systemair (1 listed model, qualified 2026-03-25). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.1 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 149.8 kWh/yr (~$23.97/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How do flex elbows choke Systemair K 5 (40404) at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 5 in. diameter metal pipe keeps Systemair K 5 (40404) moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Systemair K 5 (40404) meet residential exhaust fan code specs?

Inspect Systemair K 5 (40404) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Systemair (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | K 5 (40404) / K Series | PD ID 4577053 (Qualified 2026-03-25) |
| **Duct Connection** | 5 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Systemair K 5 (40404) airflow output?

Annual electricity figures and room square-footage ceilings below reflect Systemair K 5 (40404) tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Systemair K 5 (40404)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 149.8 kWh/yr (~$23.97/yr) | 17.1 W x 8,760 hrs / 1,000 |

## Which competing models share Systemair K 5 (40404) airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |

## How much airflow margin does Systemair K 5 (40404) give your bath?

Run a quick local room-volume check for Systemair K 5 (40404) by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Systemair K 5 (40404) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Systemair K 5 (40404) for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 5 in. diameter

## What should homeowners verify first about Systemair K 5 (40404)?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Systemair K 5 (40404).

### What electrical efficiency and runtime kWh define Systemair K 5 (40404)?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Systemair K 5 (40404) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Systemair K 5 (40404)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Systemair K 5 (40404)?

Systemair K 5 (40404) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Systemair K 5 (40404)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Systemair K 5 (40404)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Systemair K 5 (40404) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Systemair K 5 (40404) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Systemair K 5 (40404) undersized or poorly matched for a bath renovation?

Skip Systemair K 5 (40404) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Systemair K 5 (40404) CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Systemair K 5 (40404) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 5 in. diameter duct runs vital.

### How does Systemair K 5 (40404) sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Systemair K 5 (40404) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## Which GradeMark tools pair best with Systemair K 5 (40404)?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Systemair K 5 (40404).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech ODD-110HS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-110hs/)
- [Ortech ODD-110HS+MS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-110hs-ms/)
- [Fantech FGC 5 (40421) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-5-40421/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)