title: "Tech Drive FA-BF-02-L Bath Fan (70 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-02-l/
description: "ENERGY STAR specs for Tech Drive FA-BF-02-L: 70 CFM, 1.5 sones (#412 of 607), 4.0 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Tech Drive FA-BF-02-L Exhaust Fan Specifications

ENERGY STAR PD #3814681 · Bathroom/Utility Room · Qualified 2024-11-22

Verified Specification Summary

Rated for 70 CFM open-air (60.3 CFM at 0.25 in. w.g.), Tech Drive FA-BF-02-L registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-02-L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60.3 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 86.1% @ 0.25"

- **Motor Draw**: 17.5 W (6.4 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive FA-BF-02-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.3 CFM out of 70 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places FA-BF-02-L (series: FA) (PD #3814681) among 27 Tech Drive entries qualified through 2024-11-22. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Broan 744 (70.0 CFM) and Broan 744FL (70.0 CFM).

## How does Tech Drive FA-BF-02-L acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive FA-BF-02-L (1.5 sones).

## How do flex elbows choke Tech Drive FA-BF-02-L at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Tech Drive FA-BF-02-L moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Tech Drive FA-BF-02-L meet residential exhaust fan code specs?

Inspect Tech Drive FA-BF-02-L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FA-BF-02-L / FA | PD ID 3814681 (Qualified 2024-11-22) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Tech Drive FA-BF-02-L airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tech Drive FA-BF-02-L tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tech Drive FA-BF-02-L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 153.3 kWh/yr (~$24.53/yr) | 17.5 W x 8,760 hrs / 1,000 |

## Which competing models share Tech Drive FA-BF-02-L airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan 744**](https://siematic-charleston.com/ventilation-fans/broan-744/) | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan 744FL**](https://siematic-charleston.com/ventilation-fans/broan-744fl/) | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan 744LED**](https://siematic-charleston.com/ventilation-fans/broan-744led/) | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Commercial Electric 7130-18-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-18-ce/) | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan-Nutone BE8**](https://siematic-charleston.com/ventilation-fans/broan-nutone-be8/) | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |

## How much airflow margin does Tech Drive FA-BF-02-L give your bath?

Run a quick local room-volume check for Tech Drive FA-BF-02-L by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Tech Drive FA-BF-02-L?

Match Tech Drive FA-BF-02-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Tech Drive FA-BF-02-L?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive FA-BF-02-L.

### What happens to Tech Drive FA-BF-02-L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Tech Drive FA-BF-02-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.

### Where does Tech Drive FA-BF-02-L sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Tech Drive FA-BF-02-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Tech Drive FA-BF-02-L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Tech Drive FA-BF-02-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Tech Drive FA-BF-02-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-02-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive FA-BF-02-L?

Tech Drive FA-BF-02-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive FA-BF-02-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-02-L's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Tech Drive FA-BF-02-L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-02-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Tech Drive FA-BF-02-L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Tech Drive FA-BF-02-L.

## Which GradeMark tools pair best with Tech Drive FA-BF-02-L?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Tech Drive FA-BF-02-L.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech 7142-70-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/)
- [Revent RVSX50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsx50-4497569/)
- [Broan 744LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744led/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)