title: "Tech Drive TD-BF-02 Bath Fan (90 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-02/
description: "ENERGY STAR specs for Tech Drive TD-BF-02: 90 CFM, 0.8 sones (#194 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Tech Drive TD-BF-02 Exhaust Fan Specifications

ENERGY STAR PD #2382315 · Bathroom/Utility Room · Qualified 2021-07-16

Verified Specification Summary

The Tech Drive TD-BF-02 (TD) moves 90 CFM at 0.1 in. w.g. (71.5 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 71 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-02 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 71.5 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 79.4% @ 0.25"

- **Motor Draw**: 23.1 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-02 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.5 CFM at 0.25 in. w.g. (79.4% retention, 8.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, TD-BF-02 (series: TD) carries PD #2382315 dating to 2021-07-16. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.1 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 202.4 kWh/yr (~$32.38/yr) continuously. Closest competing matches include Dayton 5AE68B (90.0 CFM) and Greenheck SP-B90 (90.0 CFM).

## Where does Tech Drive TD-BF-02 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.

## How does duct geometry alter Tech Drive TD-BF-02 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Tech Drive TD-BF-02?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive TD-BF-02 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-02 / TD | PD ID 2382315 (Qualified 2021-07-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Tech Drive TD-BF-02 ventilate safely?

Sizing outputs below convert Tech Drive TD-BF-02 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-02

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 23.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 202.4 kWh/yr (~$32.38/yr) | 23.1 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Tech Drive TD-BF-02 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**KORA SBF90N**](https://siematic-charleston.com/ventilation-fans/kora-sbf90n/) | 93.7 / N/A CFM | 0.8 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Ortech ODC-9008**](https://siematic-charleston.com/ventilation-fans/ortech-odc-9008/) | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |

## Will Tech Drive TD-BF-02 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Tech Drive TD-BF-02 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Tech Drive TD-BF-02 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive TD-BF-02 for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 21 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 71 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Tech Drive TD-BF-02?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive TD-BF-02.

### Does Tech Drive TD-BF-02 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-02 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Tech Drive TD-BF-02 undersized or poorly matched for a bath renovation?

Skip Tech Drive TD-BF-02 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Tech Drive TD-BF-02 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive TD-BF-02 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Tech Drive TD-BF-02 sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, Tech Drive TD-BF-02 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Tech Drive TD-BF-02?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Tech Drive TD-BF-02 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-02's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-02?

Tech Drive TD-BF-02 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-02's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-02's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to Tech Drive TD-BF-02?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Tech Drive TD-BF-02.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-11-plus Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/)
- [Broan AER80LMB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-aer80lmb/)
- [Ortech ODC-9008 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odc-9008/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)