---
title: "Tech Drive TD-BF-06 Bath Fan (70 CFM, 0.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/
description: "ENERGY STAR specs for Tech Drive TD-BF-06: 70 CFM, 0.3 sones (#24 of 607), 4.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Tech Drive TD-BF-06 Exhaust Fan Specifications

ENERGY STAR PD #2382313 · Bathroom/Utility Room · Qualified 2021-07-16

Verified Specification Summary

Rated for 70 CFM open-air (60.4 CFM at 0.25 in. w.g.), Tech Drive TD-BF-06 registers #24 of 607 in quietness (0.3 sones) and delivers 4.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-06 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60.4 CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 86.3% @ 0.25"

- **Motor Draw**: 15.2 W (5.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-06 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.4 CFM out of 70 CFM (86.3% retention, 1.4 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Tech Drive TD-BF-06 (series: TD) under PD #2382313 (27 models registered, 2021-07-16). Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Win Air BPT14-13E (70.0 CFM) and Dayton 3DPE2 (63.0 CFM).

## How does Tech Drive TD-BF-06 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive TD-BF-06 (0.3 sones).

## How do flex elbows choke Tech Drive TD-BF-06 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Tech Drive TD-BF-06 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Tech Drive TD-BF-06 meet residential exhaust fan code specs?

Inspect Tech Drive TD-BF-06 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-06 / TD | PD ID 2382313 (Qualified 2021-07-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Tech Drive TD-BF-06 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tech Drive TD-BF-06 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-06

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 133.2 kWh/yr (~$21.31/yr) | 15.2 W x 8,760 hrs / 1,000 |

## Which competing models share Tech Drive TD-BF-06 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Win Air BPT14-13E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-13e/) | 70 / 60.4 CFM | 0.3 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| [**Dayton 3DPE2**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe2/) | 63 / N/A CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 6 in. diameter |
| [**Greenheck SP-B50**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b50/) | 63 / N/A CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF70N**](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/) | 76.5 / N/A CFM | 0.4 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80G15W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80g15w/) | 80 / 62.9 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |

## How much airflow margin does Tech Drive TD-BF-06 give your bath?

Run a quick local room-volume check for Tech Drive TD-BF-06 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Tech Drive TD-BF-06?

Compare where Tech Drive TD-BF-06 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Tech Drive TD-BF-06?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive TD-BF-06.

### Why might a contractor swap Tech Drive TD-BF-06 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Tech Drive TD-BF-06 lacks adequate reserve.

### How does Tech Drive TD-BF-06 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Tech Drive TD-BF-06 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Tech Drive TD-BF-06 quiet enough for a primary bedroom bathroom?

At 0.3 sones, Tech Drive TD-BF-06 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Tech Drive TD-BF-06 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Tech Drive TD-BF-06 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-06's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-06?

Tech Drive TD-BF-06 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-06's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-06's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Tech Drive TD-BF-06 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Tech Drive TD-BF-06 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## Which GradeMark tools pair best with Tech Drive TD-BF-06?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Tech Drive TD-BF-06.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Win Air BPT14-13E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-13e/)
- [Tech Drive TD-BF-06-plus Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06-plus/)
- [Wintek BPT15B-80H2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
