---
title: "Tech Drive TD-BF-10-H Bath Fan (110 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/
description: "ENERGY STAR specs for Tech Drive TD-BF-10-H: 110 CFM, 1.5 sones (#412 of 607), 4.8 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Tech Drive TD-BF-10-H Exhaust Fan Specifications

ENERGY STAR PD #4480281 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Certified by EPA ENERGY STAR, Tech Drive TD-BF-10-H delivers 110 CFM free-air (99 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 99 sq ft (8-ft height) or 88 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-10-H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 99 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 90.0% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-10-H vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Tech Drive TD-BF-10-H (series: TD) under PD #4480281 (27 models registered, 2025-07-25). Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include VENTECHLATION BPT14-24TG-H (110.0 CFM) and VENTECHLATION BPT14-24TGHS (110.0 CFM).

## How noisy is Tech Drive TD-BF-10-H compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Tech Drive TD-BF-10-H measures 1.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Tech Drive TD-BF-10-H airflow?

Connecting Tech Drive TD-BF-10-H through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Tech Drive TD-BF-10-H performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Tech Drive TD-BF-10-H lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-10-H / TD | PD ID 4480281 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Tech Drive TD-BF-10-H?

Calculated coverage metrics translate Tech Drive TD-BF-10-H airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-10-H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Tech Drive TD-BF-10-H?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tghs/) | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Broan 791LEDM**](https://siematic-charleston.com/ventilation-fans/broan-791ledm/) | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Commercial Electric BPT14-24OD-H**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt14-24od-h/) | 110 / 98.1 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Nutone 791LEDNTM**](https://siematic-charleston.com/ventilation-fans/nutone-791ledntm/) | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |

## Does Tech Drive TD-BF-10-H match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Tech Drive TD-BF-10-H percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Tech Drive TD-BF-10-H fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tech Drive TD-BF-10-H.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 49 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 99 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Tech Drive TD-BF-10-H?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Tech Drive TD-BF-10-H.

### Which bathroom layouts should pick a larger blower than Tech Drive TD-BF-10-H?

Do not force Tech Drive TD-BF-10-H into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Tech Drive TD-BF-10-H retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Tech Drive TD-BF-10-H produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Tech Drive TD-BF-10-H disturb adjacent bedrooms during night use?

Acoustic measurement places Tech Drive TD-BF-10-H at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Tech Drive TD-BF-10-H continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Tech Drive TD-BF-10-H draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Tech Drive TD-BF-10-H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-10-H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-10-H?

Tech Drive TD-BF-10-H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-10-H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-10-H's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Tech Drive TD-BF-10-H code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-10-H clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## Where can you explore more benchmarks around Tech Drive TD-BF-10-H?

Use the related reference pages and estimators below to cross-check Tech Drive TD-BF-10-H against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-25L-5CCT(BL) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-25l-5cct-bl/)
- [VENTECHLATION BPT14-24TG-H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/)
- [Tech Drive TD-BF-10 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
