title: "Tech Drive TD-BF-11-plus Bath Fan (90 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/
description: "ENERGY STAR specs for Tech Drive TD-BF-11-plus: 90 CFM, 0.8 sones (#194 of 607), 4.4 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Tech Drive TD-BF-11-plus Exhaust Fan Specifications

ENERGY STAR PD #4697514 · Bathroom/Utility Room · Qualified 2026-09-02

Verified Specification Summary

Homeowners specifying Tech Drive TD-BF-11-plus gain 90 CFM at 0.1 in. w.g. (79.5 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 4.4 CFM/W efficacy, venting bathrooms up to 79 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-11-plus Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 79.5 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 88.3% @ 0.25"

- **Motor Draw**: 20.5 W (7.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-11-plus vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.5 CFM out of 90 CFM (88.3% retention, 0.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Tech Drive registers 27 certified models, with SKU TD-BF-11-plus (series: TD) (PD #4697514) certified since 2026-09-02. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Air King AK90LS6 (90.0 CFM) and Dayton 5AE68B (90.0 CFM).

## What acoustic percentile does Tech Drive TD-BF-11-plus occupy among 1,145 bath blowers?

Inspect how Tech Drive TD-BF-11-plus positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Tech Drive TD-BF-11-plus best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tech Drive TD-BF-11-plus housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Tech Drive TD-BF-11-plus acoustic and static metrics stand?

Compare Tech Drive TD-BF-11-plus published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-11-plus / TD | PD ID 4697514 (Qualified 2026-09-02) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (79.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Tech Drive TD-BF-11-plus handle taller ceilings or walk-in tub steam?

Evaluate how Tech Drive TD-BF-11-plus scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-11-plus

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Tech Drive TD-BF-11-plus?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**Ortech ODC-9008**](https://siematic-charleston.com/ventilation-fans/ortech-odc-9008/) | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**BV BV-BF-01-PLUS**](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-01-plus/) | 90 / 82.9 CFM | 0.8 sones (Same) | 4.8 CFM/W | 4 in. diameter |

## Is Tech Drive TD-BF-11-plus sized right for your shower or tub room?

Check whether Tech Drive TD-BF-11-plus clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Tech Drive TD-BF-11-plus suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-11-plus for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 79.5 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Tech Drive TD-BF-11-plus?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive TD-BF-11-plus.

### Who should NOT install Tech Drive TD-BF-11-plus in a bathroom remodel?

Avoid specifying Tech Drive TD-BF-11-plus in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Tech Drive TD-BF-11-plus airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-11-plus achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Tech Drive TD-BF-11-plus occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., Tech Drive TD-BF-11-plus operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Tech Drive TD-BF-11-plus add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-11-plus averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Tech Drive TD-BF-11-plus pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-11-plus's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-11-plus?

Tech Drive TD-BF-11-plus features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-11-plus's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-11-plus's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Tech Drive TD-BF-11-plus pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-11-plus easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## How can you cross-check Tech Drive TD-BF-11-plus against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Tech Drive TD-BF-11-plus.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AER80LMB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-aer80lmb/)
- [Delta 80F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80f/)
- [Tech Drive TD-BF-02 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-02/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)