title: "Tech Drive TD-BF-11 Bath Fan (90 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11/
description: "ENERGY STAR specs for Tech Drive TD-BF-11: 90 CFM, 1.5 sones (#412 of 607), 4.0 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Tech Drive TD-BF-11 Exhaust Fan Specifications

ENERGY STAR PD #3531071 · Bathroom/Utility Room · Qualified 2024-05-24

Verified Specification Summary

Rated for 90 CFM open-air (82 CFM at 0.25 in. w.g.), Tech Drive TD-BF-11 registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 82 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-11 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 82 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 91.1% @ 0.25"

- **Motor Draw**: 22.5 W (8.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-11 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 82 CFM out of 90 CFM (91.1% retention, 3.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Tech Drive TD-BF-11 (series: TD) under PD #3531071 (27 models registered, 2024-05-24). Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.5 watts, about 8.2 kWh/yr (~$1.31/yr at $0.16/kWh) for 1 hr/day shower timers or 197.1 kWh/yr (~$31.54/yr) continuously. Closest competing matches include Akicon AK1390N1-W/B/S (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).

## How does Tech Drive TD-BF-11 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive TD-BF-11 (1.5 sones).

## How do flex elbows choke Tech Drive TD-BF-11 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Tech Drive TD-BF-11 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Tech Drive TD-BF-11 meet residential exhaust fan code specs?

Inspect Tech Drive TD-BF-11 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-11 / TD | PD ID 3531071 (Qualified 2024-05-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (82 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Tech Drive TD-BF-11 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tech Drive TD-BF-11 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-11

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 82 sq ft | 1 CFM/sq ft @ 82 CFM |
| Tall Bath (9-ft Ceiling) | Up to 72 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 32 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.2 kWh/yr (~$1.31/yr) | 22.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 197.1 kWh/yr (~$31.54/yr) | 22.5 W x 8,760 hrs / 1,000 |

## Which competing models share Tech Drive TD-BF-11 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Akicon AK1390N1-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n1-w-b-s/) | 90 / 67.4 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-s/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-W**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-w/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N3-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n3-w-b-s/) | 90 / 71.8 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |

## How much airflow margin does Tech Drive TD-BF-11 give your bath?

Run a quick local room-volume check for Tech Drive TD-BF-11 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Tech Drive TD-BF-11 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Tech Drive TD-BF-11 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 32 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 82 sq ft with 8-ft ceilings (72 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Tech Drive TD-BF-11?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive TD-BF-11.

### How much power does Tech Drive TD-BF-11 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Tech Drive TD-BF-11 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Tech Drive TD-BF-11 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-11's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-11?

Tech Drive TD-BF-11 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-11's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-11's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Tech Drive TD-BF-11 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-11 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Tech Drive TD-BF-11?

Rule out Tech Drive TD-BF-11 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Tech Drive TD-BF-11 capacity?

Because static drag at 0.25 in. w.g. lowers Tech Drive TD-BF-11 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Tech Drive TD-BF-11 compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Tech Drive TD-BF-11 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

## Which GradeMark tools pair best with Tech Drive TD-BF-11?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Tech Drive TD-BF-11.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech 7105-09-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7105-09-l/)
- [Air King AK80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80/)
- [Panasonic Eco Solutions RG-V80A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-v80a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)