#  Tech Drive TD-BF-13 Exhaust Fan Specifications

ENERGY STAR PD #4439151 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

Certified by EPA ENERGY STAR, Tech Drive TD-BF-13 delivers 50 CFM free-air (47 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 8.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 47 sq ft (8-ft height) or 41 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-13 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 47 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 8.1 CFM/W (#338/1,145)

- **Static Retention**: 94.0% @ 0.25"

- **Motor Draw**: 6.2 W (2.3 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-13 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 47 CFM out of 50 CFM (94.0% retention, 6.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, TD-BF-13 (series: TD) carries PD #4439151 dating to 2025-06-06. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.2 watts, about 2.3 kWh/yr (~$0.37/yr at $0.16/kWh) for 1 hr/day shower timers or 54.3 kWh/yr (~$8.69/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and VENTECHLATION BPT12-13E (50.0 CFM).

## How noisy is Tech Drive TD-BF-13 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Tech Drive TD-BF-13 measures 1.0 sones across the 1,145-model registry.

## Why does rigid 3 in. diameter ducting protect Tech Drive TD-BF-13 airflow?

Connecting Tech Drive TD-BF-13 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Tech Drive TD-BF-13 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Tech Drive TD-BF-13 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-13 / TD | PD ID 4439151 (Qualified 2025-06-06) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (47 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Tech Drive TD-BF-13?

Calculated coverage metrics translate Tech Drive TD-BF-13 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-13

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 47 sq ft | 1 CFM/sq ft @ 47 CFM |
| Tall Bath (9-ft Ceiling) | Up to 41 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.3 kWh/yr (~$0.37/yr) | 6.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 54.3 kWh/yr (~$8.69/yr) | 6.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Tech Drive TD-BF-13?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hampton Bay 1001357397**](https://siematic-charleston.com/ventilation-fans/hampton-bay-1001357397/) | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| [**VENTECHLATION BPT12-13E**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt12-13e/) | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| [**Revent RVL50**](https://siematic-charleston.com/ventilation-fans/revent-rvl50/) | 50 / 47 CFM | 1.1 sones (+0.10) | 7.6 CFM/W | 4 in. diameter |
| [**Revent RVLH50**](https://siematic-charleston.com/ventilation-fans/revent-rvlh50/) | 50 / 47 CFM | 1.1 sones (+0.10) | 7.6 CFM/W | 4 in. diameter |
| [**Revent RVS50**](https://siematic-charleston.com/ventilation-fans/revent-rvs50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |

## Does Tech Drive TD-BF-13 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Tech Drive TD-BF-13 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Tech Drive TD-BF-13 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-13 for your remodel.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Supplementary continuous trickle ventilation
- **Best application:** Collar pairs with 3 in. diameter duct straight outdoors

## Which homeowner questions come up most for Tech Drive TD-BF-13?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Tech Drive TD-BF-13.

### What acoustic sone tier does Tech Drive TD-BF-13 occupy in EPA filings?

With 1.0 sones at 0.1 in. w.g., Tech Drive TD-BF-13 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Tech Drive TD-BF-13 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-13 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Tech Drive TD-BF-13 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-13's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-13?

Tech Drive TD-BF-13 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-13's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-13's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Tech Drive TD-BF-13 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-13 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Tech Drive TD-BF-13 in a bathroom remodel?

Avoid specifying Tech Drive TD-BF-13 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Tech Drive TD-BF-13 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-13 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

## Where can you explore more benchmarks around Tech Drive TD-BF-13?

Use the related reference pages and estimators below to cross-check Tech Drive TD-BF-13 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION BPT12-13E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt12-13e/)
- [VOTATEC VO-FN4W18-AC-50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w18-ac-50/)
- [Tech Drive FA-BF-01-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-01-l/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)