#  Tech Drive TD-BF-17 Exhaust Fan Specifications

ENERGY STAR PD #4429496 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

Homeowners specifying Tech Drive TD-BF-17 gain 50 CFM at 0.1 in. w.g. (49.3 CFM at 0.25 in. w.g.) where it registers #380 of 607 in quietness (1.2 sones) and delivers 3.7 CFM/W efficacy, venting bathrooms up to 49 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-17 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 49.3 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 98.6% @ 0.25"

- **Motor Draw**: 13.5 W (4.9 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-17 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.3 CFM out of 50 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, TD-BF-17 (series: TD) carries PD #4429496 dating to 2025-06-06. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include VENTECHLATION BPT13-12EN-T (50.0 CFM) and VENTECHLATION BPT13-12EN3 (50.0 CFM).

## What acoustic percentile does Tech Drive TD-BF-17 occupy among 1,145 bath blowers?

Inspect how Tech Drive TD-BF-17 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Tech Drive TD-BF-17 best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Tech Drive TD-BF-17 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Tech Drive TD-BF-17 acoustic and static metrics stand?

Compare Tech Drive TD-BF-17 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-17 / TD | PD ID 4429496 (Qualified 2025-06-06) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (49.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Tech Drive TD-BF-17 handle taller ceilings or walk-in tub steam?

Evaluate how Tech Drive TD-BF-17 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-17

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 49 sq ft | 1 CFM/sq ft @ 49.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 43 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 118.3 kWh/yr (~$18.93/yr) | 13.5 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Tech Drive TD-BF-17?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**VENTECHLATION BPT13-12EN-T**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en-t/) | 50 / 49.3 CFM | 1.2 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| [**VENTECHLATION BPT13-12EN3**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en3/) | 50 / 49.3 CFM | 1.2 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| [**Commercial Electric BPT13-12EN**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-12en/) | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| [**MaxLite EBF17-50-1-W**](https://siematic-charleston.com/ventilation-fans/maxlite-ebf17-50-1-w/) | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| [**HomeWerks Worldwide 7140-50**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-50/) | 50 / 43.4 CFM | 1.0 sones (-0.20) | 3.0 CFM/W | 4 in. diameter |

## Is Tech Drive TD-BF-17 sized right for your shower or tub room?

Check whether Tech Drive TD-BF-17 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Tech Drive TD-BF-17 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive TD-BF-17 for residential use.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Supplementary continuous trickle ventilation
- **Primary match:** Collar pairs with 3 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Tech Drive TD-BF-17?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive TD-BF-17.

### Does Tech Drive TD-BF-17 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-17 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Tech Drive TD-BF-17 undersized or poorly matched for a bath renovation?

Skip Tech Drive TD-BF-17 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Tech Drive TD-BF-17 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive TD-BF-17 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

### How does Tech Drive TD-BF-17 sound output compare to noisy contractor-grade fans?

Rated at 1.2 sones, Tech Drive TD-BF-17 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Tech Drive TD-BF-17?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Tech Drive TD-BF-17 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-17's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-17?

Tech Drive TD-BF-17 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-17's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-17's safe coverage footprint from 50 sq ft to 44 sq ft.

## How can you cross-check Tech Drive TD-BF-17 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Tech Drive TD-BF-17.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION BPT13-12EN-T Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en-t/)
- [VENTECHLATION BPT13-12EN3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en3/)
- [S&P PCLP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pclp80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)