title: "Tech Drive TD-BF-24L-5CCT(BL) Bath Fan (150 CFM, 1.5 Sone)"
url: https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/
description: "ENERGY STAR specs for Tech Drive TD-BF-24L-5CCT(BL): 150 CFM, 1.5 sones (#412 of 607), 4.5 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Tech Drive TD-BF-24L-5CCT(BL) Exhaust Fan Specifications

ENERGY STAR PD #4697634 · Bathroom/Utility Room · Qualified 2026-09-02

Verified Specification Summary

In EPA dataset 8dv7-nngq, Tech Drive TD-BF-24L-5CCT(BL) tests at 150 CFM free discharge (138.2 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 138 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-24L-5CCT(BL) Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 138.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 92.1% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tech Drive TD-BF-24L-5CCT(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 138.2 CFM out of 150 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Tech Drive TD-BF-24L-5CCT(BL) (series: TD) under PD #4697634 (27 models registered, 2026-09-02). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Broan ALT4306SS (160.0 CFM).

## Does Tech Drive TD-BF-24L-5CCT(BL) fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Tech Drive TD-BF-24L-5CCT(BL) at 1.5 sones.

## Why avoid unvented attic termination with Tech Drive TD-BF-24L-5CCT(BL)?

Under ASHRAE 62.2 best practice, Tech Drive TD-BF-24L-5CCT(BL) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Tech Drive TD-BF-24L-5CCT(BL)?

Before cutting ceiling drywall or sizing attic transitions for Tech Drive TD-BF-24L-5CCT(BL), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TD-BF-24L-5CCT(BL) / TD | PD ID 4697634 (Qualified 2026-09-02) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (138.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Tech Drive TD-BF-24L-5CCT(BL)?

Bathroom ventilation sizing below maps Tech Drive TD-BF-24L-5CCT(BL) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-24L-5CCT(BL)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 138 sq ft | 1 CFM/sq ft @ 138.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 122 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 88 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Tech Drive TD-BF-24L-5CCT(BL) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Tech Drive TD-BF-24L-5CCT(BL).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones (Same) | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones (+0.20) | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |

## What percentage of room demand does Tech Drive TD-BF-24L-5CCT(BL) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Tech Drive TD-BF-24L-5CCT(BL) tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Tech Drive TD-BF-24L-5CCT(BL)?

Match Tech Drive TD-BF-24L-5CCT(BL) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 138.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 1.5 sones up to 138 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Tech Drive TD-BF-24L-5CCT(BL)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Tech Drive TD-BF-24L-5CCT(BL).

### What does Tech Drive TD-BF-24L-5CCT(BL) cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Tech Drive TD-BF-24L-5CCT(BL) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Tech Drive TD-BF-24L-5CCT(BL) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-24L-5CCT(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tech Drive TD-BF-24L-5CCT(BL)?

Tech Drive TD-BF-24L-5CCT(BL) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tech Drive TD-BF-24L-5CCT(BL)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-24L-5CCT(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Tech Drive TD-BF-24L-5CCT(BL) ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-24L-5CCT(BL) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Tech Drive TD-BF-24L-5CCT(BL) run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Tech Drive TD-BF-24L-5CCT(BL).

### What happens to Tech Drive TD-BF-24L-5CCT(BL) CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Tech Drive TD-BF-24L-5CCT(BL) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Tech Drive TD-BF-24L-5CCT(BL) sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Tech Drive TD-BF-24L-5CCT(BL) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## What related resources expand on Tech Drive TD-BF-24L-5CCT(BL)?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan QT130E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/)
- [Broan QT130LE Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/)
- [Broan QT150LE Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qt150le/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)