Verified Specification Summary

Rated for 70 CFM open-air (55.7 CFM at 0.25 in. w.g.), Tuscany 7105-11-M registers #265 of 607 in quietness (1.0 sones) and delivers 3.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 55 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tuscany 7105-11-M Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 55.7 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.4 CFM/W (#1,060/1,145)

- **Static Retention**: 79.6% @ 0.25"

- **Motor Draw**: 20.6 W (7.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Tuscany 7105-11-M vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 55.7 CFM at 0.25 in. w.g. (79.6% retention, 8.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Tuscany registers 1 certified model, with SKU 7105-11-M (series: 7105-11-M) (PD #2667914) certified since 2023-08-11. Lighting kit: Yes. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include HomeWerks Worldwide 7105-10 (70.0 CFM) and HomeWerks Worldwide 7105-10-MB (70.0 CFM).

## How does Tuscany 7105-11-M acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tuscany 7105-11-M (1.0 sones).

## How do flex elbows choke Tuscany 7105-11-M at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Tuscany 7105-11-M moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Tuscany 7105-11-M meet residential exhaust fan code specs?

Inspect Tuscany 7105-11-M mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Tuscany (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7105-11-M / 7105-11-M | PD ID 2667914 (Qualified 2023-08-11) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (55.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Tuscany 7105-11-M airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tuscany 7105-11-M tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tuscany 7105-11-M

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 55 sq ft | 1 CFM/sq ft @ 55.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 49 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |

## Which competing models share Tuscany 7105-11-M airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7105-10**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-10/) | 70 / 55.7 CFM | 1.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7105-10-MB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-10-mb/) | 70 / 55.7 CFM | 1.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Nektra 33003851**](https://siematic-charleston.com/ventilation-fans/nektra-33003851/) | 70 / 55.7 CFM | 1.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80/) | 70 / 60.5 CFM | 1.1 sones (+0.10) | 3.4 CFM/W | 3 in. diameter |
| [**Broan LP80**](https://siematic-charleston.com/ventilation-fans/broan-lp80/) | 70 / 60.5 CFM | 1.1 sones (+0.10) | 3.4 CFM/W | 3 in. diameter |

## How much airflow margin does Tuscany 7105-11-M give your bath?

Run a quick local room-volume check for Tuscany 7105-11-M by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Tuscany 7105-11-M on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Tuscany 7105-11-M carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 55 sq ft with 8-ft ceilings (49 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Tuscany 7105-11-M?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tuscany 7105-11-M.

### How does Tuscany 7105-11-M score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Tuscany 7105-11-M delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Tuscany 7105-11-M?

Rule out Tuscany 7105-11-M when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Tuscany 7105-11-M capacity?

Because static drag at 0.25 in. w.g. lowers Tuscany 7105-11-M from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Tuscany 7105-11-M compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Tuscany 7105-11-M operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Tuscany 7105-11-M consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Tuscany 7105-11-M draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Tuscany 7105-11-M pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tuscany 7105-11-M's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Tuscany 7105-11-M?

Tuscany 7105-11-M features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Tuscany 7105-11-M's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tuscany 7105-11-M's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Tuscany 7105-11-M?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Tuscany 7105-11-M.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Commercial Electric BF1101 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1101/)
- [Commercial Electric BF1103 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1103/)
- [Nektra 33003851 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-33003851/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)