title: "Utilitech 7105-08-L Bath Fan (80 CFM, 1.1 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/utilitech-7105-08-l/
description: "ENERGY STAR specs for Utilitech 7105-08-L: 80 CFM, 1.1 sones (#357 of 607), 3.5 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Utilitech 7105-08-L Exhaust Fan Specifications

ENERGY STAR PD #2395527 · Bathroom/Utility Room · Qualified 2022-04-01

Verified Specification Summary

In EPA dataset 8dv7-nngq, Utilitech 7105-08-L tests at 80 CFM free discharge (59.9 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 3.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 59 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7105-08-L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 59.9 CFM

- **Noise @ 0.1"**: 1.1 sones (#357/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 74.9% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Utilitech 7105-08-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.9 CFM at 0.25 in. w.g. (74.9% retention, 12.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Utilitech 7105-08-L (series: 7105-08-L) under PD #2395527 (22 models registered, 2022-04-01). Lighting kit: Yes. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Broan (Canada) EZ80C (80.0 CFM) and Commercial Electric 7132-12-CE (80.0 CFM).

## Does Utilitech 7105-08-L fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Utilitech 7105-08-L at 1.1 sones.

## Why avoid unvented attic termination with Utilitech 7105-08-L?

Under ASHRAE 62.2 best practice, Utilitech 7105-08-L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Utilitech 7105-08-L?

Before cutting ceiling drywall or sizing attic transitions for Utilitech 7105-08-L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Utilitech (22 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7105-08-L / 7105-08-L | PD ID 2395527 (Qualified 2022-04-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (59.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Utilitech 7105-08-L?

Bathroom ventilation sizing below maps Utilitech 7105-08-L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Utilitech 7105-08-L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Utilitech 7105-08-L in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Utilitech 7105-08-L.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan (Canada) EZ80C**](https://siematic-charleston.com/ventilation-fans/broan-canada-ez80c-2406836/) | 80 / 65.6 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Commercial Electric 7132-12-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7132-12-ce/) | 80 / 57.1 CFM | 1.1 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-G4**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-g4/) | 80 / 61.2 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80/) | 80 / 62.9 CFM | 1.1 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Air King LEDAK80**](https://siematic-charleston.com/ventilation-fans/air-king-ledak80/) | 80 / 70.3 CFM | 1.2 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |

## What percentage of room demand does Utilitech 7105-08-L cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Utilitech 7105-08-L tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Utilitech 7105-08-L fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Utilitech 7105-08-L.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 59.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 1.1 sones up to 59 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Utilitech 7105-08-L?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Utilitech 7105-08-L.

### Will Utilitech 7105-08-L disturb adjacent bedrooms during night use?

Acoustic measurement places Utilitech 7105-08-L at 1.1 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Utilitech 7105-08-L continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Utilitech 7105-08-L draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Utilitech 7105-08-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7105-08-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Utilitech 7105-08-L?

Utilitech 7105-08-L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Utilitech 7105-08-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7105-08-L's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Utilitech 7105-08-L code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Utilitech 7105-08-L clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Utilitech 7105-08-L?

Do not force Utilitech 7105-08-L into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Utilitech 7105-08-L retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Utilitech 7105-08-L produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## What related resources expand on Utilitech 7105-08-L?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan EZ80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ez80/)
- [Broan LP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-lp80/)
- [HomeWerks Worldwide 7141-80-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-g4/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)