title: "Utilitech 7111-04-L Bath Fan (70 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/utilitech-7111-04-l/
description: "ENERGY STAR specs for Utilitech 7111-04-L: 70 CFM, 2.0 sones (#522 of 607), 7.0 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Utilitech 7111-04-L Exhaust Fan Specifications

ENERGY STAR PD #2343309 · Bathroom/Utility Room · Qualified 2017-02-24

Verified Specification Summary

Rated for 70 CFM open-air (56.5 CFM at 0.25 in. w.g.), Utilitech 7111-04-L registers #522 of 607 in quietness (2.0 sones) and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 56 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7111-04-L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 56.5 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 7.0 CFM/W (#420/1,145)

- **Static Retention**: 80.7% @ 0.25"

- **Motor Draw**: 10.0 W (3.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Utilitech 7111-04-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 56.5 CFM at 0.25 in. w.g. (80.7% retention, 7.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2343309 verifies 7111-04-L (series: Slim) under Utilitech (22 listed models, qualified 2017-02-24). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Delta SLM70D (70.0 CFM) and Delta SLM70D2 (70.0 CFM).

## How does Utilitech 7111-04-L acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Utilitech 7111-04-L (2.0 sones).

## How do flex elbows choke Utilitech 7111-04-L at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Utilitech 7111-04-L moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Utilitech 7111-04-L meet residential exhaust fan code specs?

Inspect Utilitech 7111-04-L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Utilitech (22 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7111-04-L / Slim | PD ID 2343309 (Qualified 2017-02-24) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (56.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Utilitech 7111-04-L airflow output?

Annual electricity figures and room square-footage ceilings below reflect Utilitech 7111-04-L tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Utilitech 7111-04-L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 56 sq ft | 1 CFM/sq ft @ 56.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 50 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 10.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 87.6 kWh/yr (~$14.02/yr) | 10.0 W x 8,760 hrs / 1,000 |

## Which competing models share Utilitech 7111-04-L airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta SLM70D**](https://siematic-charleston.com/ventilation-fans/delta-slm70d/) | 70 / 56.1 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| [**Delta SLM70D2**](https://siematic-charleston.com/ventilation-fans/delta-slm70d2/) | 70 / 60.5 CFM | Unpublished | 7.0 CFM/W | 3 in. diameter |
| [**Revent RVL70**](https://siematic-charleston.com/ventilation-fans/revent-rvl70/) | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| [**Revent RVLH70**](https://siematic-charleston.com/ventilation-fans/revent-rvlh70/) | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| [**Revent RVS70**](https://siematic-charleston.com/ventilation-fans/revent-rvs70/) | 70 / 76 CFM | 2.0 sones (Same) | 7.8 CFM/W | 4 in. diameter |

## How much airflow margin does Utilitech 7111-04-L give your bath?

Run a quick local room-volume check for Utilitech 7111-04-L by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Utilitech 7111-04-L in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Utilitech 7111-04-L for residential use.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 56 sq ft with 8-ft ceilings (50 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Utilitech 7111-04-L?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech 7111-04-L.

### When is Utilitech 7111-04-L undersized or poorly matched for a bath renovation?

Skip Utilitech 7111-04-L if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Utilitech 7111-04-L CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Utilitech 7111-04-L registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

### How does Utilitech 7111-04-L sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Utilitech 7111-04-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Utilitech 7111-04-L?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Utilitech 7111-04-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7111-04-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Utilitech 7111-04-L?

Utilitech 7111-04-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Utilitech 7111-04-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7111-04-L's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Utilitech 7111-04-L satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Utilitech 7111-04-L clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Which GradeMark tools pair best with Utilitech 7111-04-L?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Utilitech 7111-04-L.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION BPT13-13EN-T Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-13en-t/)
- [VENTECHLATION BPT13-13EN3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-13en3/)
- [Tech Drive TD-BF-03-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-03-1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)