#  Utilitech 7114-02-L Exhaust Fan Specifications

ENERGY STAR PD #4016318 · Bathroom/Utility Room · Qualified 2025-04-11

Verified Specification Summary

Tested under HVI protocols, the Utilitech 7114-02-L exhaust unit achieves 50 CFM at 0.1 in. w.g. (36.9 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 10.2 CFM/W efficacy, covering standard baths up to 36 sq ft on a 3 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7114-02-L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 36.9 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 10.2 CFM/W (#179/1,145)

- **Static Retention**: 73.8% @ 0.25"

- **Motor Draw**: 4.9 W (1.8 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Utilitech 7114-02-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.9 CFM at 0.25 in. w.g. (73.8% retention, 13.9 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Utilitech 7114-02-L (series: 7114-02-L) under PD #4016318 (22 models registered, 2025-04-11). Lighting kit: Yes. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.9 watts, about 1.8 kWh/yr (~$0.29/yr at $0.16/kWh) for 1 hr/day shower timers or 42.9 kWh/yr (~$6.86/yr) continuously. Closest competing matches include Hampton Bay 7114-02 (50.0 CFM) and HomeWerks Worldwide 7114-02-HW (50.0 CFM).

## Where do Utilitech 7114-02-L sones rank across EPA ENERGY STAR fans?

Comparing Utilitech 7114-02-L (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Utilitech 7114-02-L CFM output?

Short straight 3 in. diameter duct paths retain up to ~82% of open-air capacity on Utilitech 7114-02-L, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Utilitech 7114-02-L measure up on airflow and noise ratings?

Each row below breaks down Utilitech 7114-02-L certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Utilitech (22 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7114-02-L / 7114-02-L | PD ID 4016318 (Qualified 2025-04-11) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (36.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Utilitech 7114-02-L CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Utilitech 7114-02-L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.8 kWh/yr (~$0.29/yr) | 4.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 42.9 kWh/yr (~$6.86/yr) | 4.9 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Utilitech 7114-02-L?

Compare Utilitech 7114-02-L side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hampton Bay 7114-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7114-02/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**HomeWerks Worldwide 7114-02-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Revent RVS50**](https://siematic-charleston.com/ventilation-fans/revent-rvs50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| [**Revent RVSH50**](https://siematic-charleston.com/ventilation-fans/revent-rvsh50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| [**Delta 50F**](https://siematic-charleston.com/ventilation-fans/delta-50f/) | 50 / 41.3 CFM | 1.0 sones (Same) | 11.6 CFM/W | 3 in. diameter |

## Can you size Utilitech 7114-02-L for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Utilitech 7114-02-L verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Utilitech 7114-02-L?

Match Utilitech 7114-02-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 36.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 1.0 sones up to 36 sq ft
- **Optimal use:** Paired with rigid galvanized 3 in. diameter transition

## How do federal and code standards apply to Utilitech 7114-02-L?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Utilitech 7114-02-L.

### What bathroom square footage can Utilitech 7114-02-L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7114-02-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Utilitech 7114-02-L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7114-02-L.

### What happens to Utilitech 7114-02-L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Utilitech 7114-02-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.

### Where does Utilitech 7114-02-L sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, Utilitech 7114-02-L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Utilitech 7114-02-L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Utilitech 7114-02-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Utilitech 7114-02-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7114-02-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Utilitech 7114-02-L?

Utilitech 7114-02-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Utilitech 7114-02-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7114-02-L's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Utilitech 7114-02-L?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Utilitech 7114-02-L.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [DewStop - Breeze Easy BEL110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/)
- [Revent RVL110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvl110/)
- [HomeWerks Worldwide 7114-02-HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)