---
title: "Utilitech 7115-02-CH Bath Fan (100 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/
description: "ENERGY STAR specs for Utilitech 7115-02-CH: 100 CFM, 1.5 sones (#412 of 607), 7.8 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Utilitech 7115-02-CH Exhaust Fan Specifications

ENERGY STAR PD #2406849 · Bathroom/Utility Room · Qualified 2023-01-13

Verified Specification Summary

The Utilitech 7115-02-CH (Utilitech) moves 100 CFM at 0.1 in. w.g. (84.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 7.8 CFM/W efficacy, sizing bathrooms up to 84 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7115-02-CH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 84.9 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 7.8 CFM/W (#365/1,145)

- **Static Retention**: 84.9% @ 0.25"

- **Motor Draw**: 12.8 W (4.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Utilitech 7115-02-CH vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.9 CFM at 0.25 in. w.g. (84.9% retention, 2.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Utilitech's 22-unit lineup, 7115-02-CH (series: Utilitech) carries PD #2406849 dating to 2023-01-13. Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.8 watts, about 4.7 kWh/yr (~$0.75/yr at $0.16/kWh) for 1 hr/day shower timers or 112.1 kWh/yr (~$17.94/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).

## Where does Utilitech 7115-02-CH sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

## How does duct geometry alter Utilitech 7115-02-CH static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Utilitech 7115-02-CH?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Utilitech 7115-02-CH alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Utilitech (22 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7115-02-CH / Utilitech | PD ID 2406849 (Qualified 2023-01-13) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Utilitech 7115-02-CH ventilate safely?

Sizing outputs below convert Utilitech 7115-02-CH tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Utilitech 7115-02-CH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.7 kWh/yr (~$0.75/yr) | 12.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 112.1 kWh/yr (~$17.94/yr) | 12.8 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Utilitech 7115-02-CH closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100**](https://siematic-charleston.com/ventilation-fans/delta-itg100/) | 100 / 88 CFM | 1.5 sones (Same) | 7.6 CFM/W | 4 in. diameter |
| [**Delta 100LED**](https://siematic-charleston.com/ventilation-fans/delta-100led/) | 100 / 75 CFM | 1.5 sones (Same) | 7.4 CFM/W | 4 in. diameter |
| [**Delta GBR100LED**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led/) | 100 / 75 CFM | 1.5 sones (Same) | 7.4 CFM/W | 4 in. diameter |

## Will Utilitech 7115-02-CH clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Utilitech 7115-02-CH satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Utilitech 7115-02-CH suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Utilitech 7115-02-CH for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Utilitech 7115-02-CH?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Utilitech 7115-02-CH.

### How many kWh per year does Utilitech 7115-02-CH add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Utilitech 7115-02-CH averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Utilitech 7115-02-CH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7115-02-CH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Utilitech 7115-02-CH?

Utilitech 7115-02-CH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Utilitech 7115-02-CH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7115-02-CH's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Utilitech 7115-02-CH pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7115-02-CH easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Utilitech 7115-02-CH in a bathroom remodel?

Avoid specifying Utilitech 7115-02-CH in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Utilitech 7115-02-CH airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Utilitech 7115-02-CH achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Utilitech 7115-02-CH occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Utilitech 7115-02-CH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Which guides and calculators connect next to Utilitech 7115-02-CH?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Utilitech 7115-02-CH.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech 7115-02-MB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-mb/)
- [Utilitech 7115-03 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-03/)
- [Utilitech 7115-02-BN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
