title: "Utilitech 7116-02 Bath Fan (150 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/utilitech-7116-02/
description: "ENERGY STAR specs for Utilitech 7116-02: 150 CFM, 1.0 sones (#265 of 607), 8.1 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Utilitech 7116-02 Exhaust Fan Specifications

ENERGY STAR PD #2343326 · Bathroom/Utility Room · Qualified 2017-11-10

Verified Specification Summary

Rated for 150 CFM open-air (123.8 CFM at 0.25 in. w.g.), Utilitech 7116-02 registers #265 of 607 in quietness (1.0 sones) and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 123 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7116-02 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 123.8 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 8.1 CFM/W (#338/1,145)

- **Static Retention**: 82.5% @ 0.25"

- **Motor Draw**: 18.5 W (6.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Utilitech 7116-02 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Utilitech 7116-02 (series: Utilitech) under PD #2343326 (22 models registered, 2017-11-10). Lighting kit: Yes. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.5 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.1 kWh/yr (~$25.94/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and ACIQ AEPD150SC (150.0 CFM).

## How does Utilitech 7116-02 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Utilitech 7116-02 (1.0 sones).

## How do flex elbows choke Utilitech 7116-02 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Utilitech 7116-02 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Utilitech 7116-02 meet residential exhaust fan code specs?

Inspect Utilitech 7116-02 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Utilitech (22 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7116-02 / Utilitech | PD ID 2343326 (Qualified 2017-11-10) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Utilitech 7116-02 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Utilitech 7116-02 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Utilitech 7116-02

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.1 kWh/yr (~$25.94/yr) | 18.5 W x 8,760 hrs / 1,000 |

## Which competing models share Utilitech 7116-02 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones (+0.30) | 8.7 CFM/W | 4 in. diameter |
| [**ACIQ AEPD150SC**](https://siematic-charleston.com/ventilation-fans/aciq-aepd150sc/) | 150 / 130.3 CFM | 0.9 sones (-0.10) | 11.4 CFM/W | 6 in. diameter |
| [**OREiN OL1700376**](https://siematic-charleston.com/ventilation-fans/orein-ol1700376/) | 160 / 152 CFM | 1.0 sones (Same) | 4.8 CFM/W | 6 in. diameter |
| [**Air King AK150LS**](https://siematic-charleston.com/ventilation-fans/air-king-ak150ls/) | 150 / 124.4 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-19**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-19/) | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |

## How much airflow margin does Utilitech 7116-02 give your bath?

Run a quick local room-volume check for Utilitech 7116-02 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Utilitech 7116-02?

Match Utilitech 7116-02 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 73 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 123 sq ft with 8-ft ceilings (110 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Utilitech 7116-02?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech 7116-02.

### What does Utilitech 7116-02 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Utilitech 7116-02 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Utilitech 7116-02 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7116-02's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Utilitech 7116-02?

Utilitech 7116-02 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Utilitech 7116-02's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7116-02's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Utilitech 7116-02 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7116-02 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Utilitech 7116-02 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7116-02.

### What happens to Utilitech 7116-02 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Utilitech 7116-02 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Utilitech 7116-02 sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, Utilitech 7116-02 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## Which GradeMark tools pair best with Utilitech 7116-02?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Utilitech 7116-02.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Hampton Bay 7136-02 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/hampton-bay-7136-02/)
- [HomeWerks Worldwide 7136-02HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7136-02hw/)
- [VENTECHLATION VF-BF-06 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-06/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)