title: "Valu+ BPT13-14DT-2 Bath Fan (80 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/valu-bpt13-14dt-2/
description: "ENERGY STAR specs for Valu+ BPT13-14DT-2: 80 CFM, 1.5 sones (#412 of 607), 4.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Valu+ BPT13-14DT-2 Exhaust Fan Specifications

ENERGY STAR PD #4514485 · Bathroom/Utility Room · Qualified 2025-10-03

Verified Specification Summary

Certified by EPA ENERGY STAR, Valu+ BPT13-14DT-2 delivers 80 CFM free-air (57.7 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 57 sq ft (8-ft height) or 51 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Valu+ BPT13-14DT-2 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 57.7 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 72.1% @ 0.25"

- **Motor Draw**: 18.6 W (6.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Valu+ BPT13-14DT-2 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Valu+ registers 2 certified models, with SKU BPT13-14DT-2 (series: BPT13) (PD #4514485) certified since 2025-10-03. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Commercial Electric BPT13-14D (80.0 CFM).

## How noisy is Valu+ BPT13-14DT-2 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Valu+ BPT13-14DT-2 measures 1.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Valu+ BPT13-14DT-2 airflow?

Connecting Valu+ BPT13-14DT-2 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Valu+ BPT13-14DT-2 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Valu+ BPT13-14DT-2 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Valu+ (2 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT13-14DT-2 / BPT13 | PD ID 4514485 (Qualified 2025-10-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (57.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Valu+ BPT13-14DT-2?

Calculated coverage metrics translate Valu+ BPT13-14DT-2 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Valu+ BPT13-14DT-2

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Valu+ BPT13-14DT-2?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK80**](https://siematic-charleston.com/ventilation-fans/air-king-ak80/) | 80 / 68.8 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Commercial Electric BPT13-14D**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-14d/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Commercial Electric BPT13-14HD**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-14hd/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-04**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-04-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-h/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |

## Does Valu+ BPT13-14DT-2 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Valu+ BPT13-14DT-2 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Valu+ BPT13-14DT-2 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Valu+ BPT13-14DT-2 for residential use.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 57.7 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Valu+ BPT13-14DT-2?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Valu+ BPT13-14DT-2.

### When is Valu+ BPT13-14DT-2 undersized or poorly matched for a bath renovation?

Skip Valu+ BPT13-14DT-2 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Valu+ BPT13-14DT-2 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Valu+ BPT13-14DT-2 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Valu+ BPT13-14DT-2 sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, Valu+ BPT13-14DT-2 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Valu+ BPT13-14DT-2?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Valu+ BPT13-14DT-2 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Valu+ BPT13-14DT-2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Valu+ BPT13-14DT-2?

Valu+ BPT13-14DT-2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Valu+ BPT13-14DT-2's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Valu+ BPT13-14DT-2's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Valu+ BPT13-14DT-2 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Valu+ BPT13-14DT-2 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Where can you explore more benchmarks around Valu+ BPT13-14DT-2?

Use the related reference pages and estimators below to cross-check Valu+ BPT13-14DT-2 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION BPT13-14DT-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-14dt-1/)
- [VENTECHLATION BPT13-14HD-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-14hd-1/)
- [Tech Drive TD-BF-04-H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-h/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)