title: "Valu+ BPT14-24TGHS Bath Fan (110 CFM, 1.2 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/valu-bpt14-24tghs/
description: "ENERGY STAR specs for Valu+ BPT14-24TGHS: 110 CFM, 1.2 sones (#380 of 607), 4.8 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Valu+ BPT14-24TGHS Exhaust Fan Specifications

ENERGY STAR PD #3999573 · Bathroom/Utility Room · Qualified 2025-03-07

Verified Specification Summary

In EPA dataset 8dv7-nngq, Valu+ BPT14-24TGHS tests at 110 CFM free discharge (99 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 99 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Valu+ BPT14-24TGHS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 99 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 90.0% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Valu+ BPT14-24TGHS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Valu+ registers 2 certified models, with SKU BPT14-24TGHS (series: 1) (PD #3999573) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include BV BV-BF-02-PLUS (110.0 CFM) and Nektra 3291028 (110.0 CFM).

## Does Valu+ BPT14-24TGHS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Valu+ BPT14-24TGHS at 1.2 sones.

## Why avoid unvented attic termination with Valu+ BPT14-24TGHS?

Under ASHRAE 62.2 best practice, Valu+ BPT14-24TGHS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Valu+ BPT14-24TGHS?

Before cutting ceiling drywall or sizing attic transitions for Valu+ BPT14-24TGHS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Valu+ (2 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT14-24TGHS / 1 | PD ID 3999573 (Qualified 2025-03-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Valu+ BPT14-24TGHS?

Bathroom ventilation sizing below maps Valu+ BPT14-24TGHS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Valu+ BPT14-24TGHS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Valu+ BPT14-24TGHS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Valu+ BPT14-24TGHS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**BV BV-BF-02-PLUS**](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-02-plus/) | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Nektra 3291028**](https://siematic-charleston.com/ventilation-fans/nektra-3291028/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Win Air BPT14-24E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24e/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**COSTWAY BPT14-24A-A-1**](https://siematic-charleston.com/ventilation-fans/costway-bpt14-24a-a-1/) | 110 / 97.5 CFM | 1.2 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Loren Cook Company GC-222**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-222/) | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |

## What percentage of room demand does Valu+ BPT14-24TGHS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Valu+ BPT14-24TGHS tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Valu+ BPT14-24TGHS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Valu+ BPT14-24TGHS for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 99 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 1.2 sones up to 99 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Valu+ BPT14-24TGHS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Valu+ BPT14-24TGHS.

### Does Valu+ BPT14-24TGHS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Valu+ BPT14-24TGHS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Valu+ BPT14-24TGHS undersized or poorly matched for a bath renovation?

Skip Valu+ BPT14-24TGHS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Valu+ BPT14-24TGHS CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Valu+ BPT14-24TGHS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Valu+ BPT14-24TGHS sound output compare to noisy contractor-grade fans?

Rated at 1.2 sones, Valu+ BPT14-24TGHS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Valu+ BPT14-24TGHS?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Valu+ BPT14-24TGHS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Valu+ BPT14-24TGHS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Valu+ BPT14-24TGHS?

Valu+ BPT14-24TGHS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Valu+ BPT14-24TGHS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Valu+ BPT14-24TGHS's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on Valu+ BPT14-24TGHS?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Win Air BPT14-24E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24e/)
- [HomeWerks Worldwide 7130-40-BT Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7130-40-bt/)
- [Nektra 3291028 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-3291028/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)