#  Venco SP-LP0810WL Exhaust Fan Specifications

ENERGY STAR PD #3629319 · Bathroom/Utility Room · Qualified 2024-09-13

Verified Specification Summary

Rated for 100 CFM open-air (106.9 CFM at 0.25 in. w.g.), Venco SP-LP0810WL omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 106 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco SP-LP0810WL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.5 CFM/W (#234/1,145)

- **Static Retention**: 106.9% @ 0.25"

- **Motor Draw**: 10.5 W (3.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Venco SP-LP0810WL vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco SP-LP0810WL (EPA filing PD #3629319) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.9 CFM out of 100 CFM (106.9% retention, 19.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Venco maintains 15 active ENERGY STAR blowers; SP-LP0810WL (series: Model SP Ceiling Fan, Direct Drive) (PD #3629319) gained qualification on 2024-09-13. Lighting kit: Yes. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## How do flex elbows choke Venco SP-LP0810WL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Venco SP-LP0810WL moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Venco SP-LP0810WL meet residential exhaust fan code specs?

Inspect Venco SP-LP0810WL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Venco (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-LP0810WL / Model SP Ceiling Fan, Direct Drive | PD ID 3629319 (Qualified 2024-09-13) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Venco SP-LP0810WL airflow output?

Annual electricity figures and room square-footage ceilings below reflect Venco SP-LP0810WL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Venco SP-LP0810WL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |

## Which competing models share Venco SP-LP0810WL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## How much airflow margin does Venco SP-LP0810WL give your bath?

Run a quick local room-volume check for Venco SP-LP0810WL by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Venco SP-LP0810WL in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Venco SP-LP0810WL for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 56 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 106 sq ft with 8-ft ceilings (95 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Venco SP-LP0810WL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Venco SP-LP0810WL.

### How does Venco SP-LP0810WL sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Venco SP-LP0810WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Venco SP-LP0810WL?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Venco SP-LP0810WL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco SP-LP0810WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Venco SP-LP0810WL?

Venco SP-LP0810WL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Venco SP-LP0810WL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco SP-LP0810WL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Venco SP-LP0810WL satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Venco SP-LP0810WL clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Venco SP-LP0810WL undersized or poorly matched for a bath renovation?

Skip Venco SP-LP0810WL if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Venco SP-LP0810WL CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Venco SP-LP0810WL registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## Which GradeMark tools pair best with Venco SP-LP0810WL?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Venco SP-LP0810WL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Venco VQ-LP0810W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0810w/)
- [Venco VQ-LP0810WL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0810wl/)
- [Venco SP-LP0810W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-sp-lp0810w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)