#  Venco VQ-AP0511W-1 Exhaust Fan Specifications

ENERGY STAR PD #4015811 · Bathroom/Utility Room · Qualified 2025-02-07

Verified Specification Summary

Tested under HVI protocols, the Venco VQ-AP0511W-1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (126.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, covering standard baths up to 126 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-AP0511W-1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 126.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.8 CFM/W (#90/1,145)

- **Static Retention**: 114.6% @ 0.25"

- **Motor Draw**: 9.3 W (3.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Venco VQ-AP0511W-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-AP0511W-1 (EPA filing PD #4015811) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.1 CFM out of 110 CFM (114.6% retention, 26.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places VQ-AP0511W-1 (series: Model SP Ceiling Fan, Direct Drive) (PD #4015811) among 15 Venco entries qualified through 2025-02-07. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.3 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 81.5 kWh/yr (~$13.04/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

## What attic duct routing preserves Venco VQ-AP0511W-1 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Venco VQ-AP0511W-1, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Venco VQ-AP0511W-1 measure up on airflow and noise ratings?

Each row below breaks down Venco VQ-AP0511W-1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Venco (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VQ-AP0511W-1 / Model SP Ceiling Fan, Direct Drive | PD ID 4015811 (Qualified 2025-02-07) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Venco VQ-AP0511W-1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Venco VQ-AP0511W-1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.4 kWh/yr (~$0.54/yr) | 9.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 81.5 kWh/yr (~$13.04/yr) | 9.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Venco VQ-AP0511W-1?

Compare Venco VQ-AP0511W-1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |

## Can you size Venco VQ-AP0511W-1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Venco VQ-AP0511W-1 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Venco VQ-AP0511W-1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Venco VQ-AP0511W-1 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 126.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 126 sq ft
- **Primary match:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Venco VQ-AP0511W-1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Venco VQ-AP0511W-1.

### Why check Venco VQ-AP0511W-1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Venco VQ-AP0511W-1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Venco VQ-AP0511W-1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Venco VQ-AP0511W-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Venco VQ-AP0511W-1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Venco VQ-AP0511W-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-AP0511W-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Venco VQ-AP0511W-1?

Venco VQ-AP0511W-1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Venco VQ-AP0511W-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-AP0511W-1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Venco VQ-AP0511W-1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Venco VQ-AP0511W-1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Venco VQ-AP0511W-1 undersized or poorly matched for a bath renovation?

Skip Venco VQ-AP0511W-1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What neighboring pages and tools support Venco VQ-AP0511W-1?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Venco VQ-AP0511W-1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Venco VQ-AP0511W-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511w-1-4015812/)
- [Venco VQ-AP0511W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511w-4015808/)
- [Venco VQ-AP0511W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)