---
title: "Venco VQ-AP0511WL Bath Fan (110 (wl-4667659) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511wl-4667659/
description: "ENERGY STAR specs for Venco VQ-AP0511WL: 110 CFM, 8.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Venco VQ-AP0511WL Exhaust Fan Specifications

ENERGY STAR PD #4667659 · Bathroom/Utility Room · Qualified 2026-07-08

Verified Specification Summary

In EPA dataset 8dv7-nngq, Venco VQ-AP0511WL tests at 110 CFM free discharge (123.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 123 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-AP0511WL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 123.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.7 CFM/W (#306/1,145)

- **Static Retention**: 112.6% @ 0.25"

- **Motor Draw**: 12.6 W (4.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Venco VQ-AP0511WL vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-AP0511WL (EPA filing PD #4667659) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 123.9 CFM out of 110 CFM (112.6% retention, 24.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4667659 verifies VQ-AP0511WL (series: Model SP Ceiling Fan, Direct Drive) under Venco (15 listed models, qualified 2026-07-08). Lighting kit: Yes. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.6 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 110.4 kWh/yr (~$17.66/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## Why avoid unvented attic termination with Venco VQ-AP0511WL?

Under ASHRAE 62.2 best practice, Venco VQ-AP0511WL needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Venco VQ-AP0511WL?

Before cutting ceiling drywall or sizing attic transitions for Venco VQ-AP0511WL, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Venco (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VQ-AP0511WL / Model SP Ceiling Fan, Direct Drive | PD ID 4667659 (Qualified 2026-07-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (123.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Venco VQ-AP0511WL?

Bathroom ventilation sizing below maps Venco VQ-AP0511WL motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Venco VQ-AP0511WL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.6 kWh/yr (~$0.74/yr) | 12.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 110.4 kWh/yr (~$17.66/yr) | 12.6 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Venco VQ-AP0511WL in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Venco VQ-AP0511WL.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## What percentage of room demand does Venco VQ-AP0511WL cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Venco VQ-AP0511WL tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Venco VQ-AP0511WL?

Compare where Venco VQ-AP0511WL excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 123.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around ENERGY STAR sones up to 123 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Venco VQ-AP0511WL?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Venco VQ-AP0511WL.

### Is Venco VQ-AP0511WL energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Venco VQ-AP0511WL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-AP0511WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Venco VQ-AP0511WL?

Venco VQ-AP0511WL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Venco VQ-AP0511WL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-AP0511WL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Venco VQ-AP0511WL serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Venco VQ-AP0511WL supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Venco VQ-AP0511WL for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Venco VQ-AP0511WL lacks adequate reserve.

### How does Venco VQ-AP0511WL handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Venco VQ-AP0511WL yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Venco VQ-AP0511WL quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Venco VQ-AP0511WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## What related resources expand on Venco VQ-AP0511WL?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Venco VQ-LP0511HL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0511hl/)
- [Venco VQ-LP0511L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0511l/)
- [Venco VQ-AP0511WL-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511wl-1-4667657/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
