title: "Venco VQ-LP0511HL Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/venco-vq-lp0511hl/
description: "ENERGY STAR specs for Venco VQ-LP0511HL: 110 CFM, 8.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Venco VQ-LP0511HL Exhaust Fan Specifications

ENERGY STAR PD #4517839 · Bathroom/Utility Room · Qualified 2025-12-05

Verified Specification Summary

Certified by EPA ENERGY STAR, Venco VQ-LP0511HL delivers 110 CFM free-air (117.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 117 sq ft (8-ft height) or 104 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Venco VQ-LP0511HL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 117.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.3 CFM/W (#321/1,145)

- **Static Retention**: 107.0% @ 0.25"

- **Motor Draw**: 13.3 W (4.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Venco VQ-LP0511HL vs. 1,145-Model ENERGY STAR Benchmarks show?

Venco VQ-LP0511HL (EPA filing PD #4517839) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 117.7 CFM out of 110 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Venco maintains 15 active ENERGY STAR blowers; VQ-LP0511HL (series: Model SP Ceiling Fan, Direct Drive) (PD #4517839) gained qualification on 2025-12-05. Lighting kit: Yes. At 8.3 CFM/W (#321 of 1,145, top 28.7% of 1,145 rated models, more efficient than 71.3% of rated models, 3.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.3 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 116.5 kWh/yr (~$18.64/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect Venco VQ-LP0511HL airflow?

Connecting Venco VQ-LP0511HL through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Venco VQ-LP0511HL performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Venco VQ-LP0511HL lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Venco (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VQ-LP0511HL / Model SP Ceiling Fan, Direct Drive | PD ID 4517839 (Qualified 2025-12-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (117.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Venco VQ-LP0511HL?

Calculated coverage metrics translate Venco VQ-LP0511HL airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Venco VQ-LP0511HL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 117 sq ft | 1 CFM/sq ft @ 117.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 104 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 67 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 116.5 kWh/yr (~$18.64/yr) | 13.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Venco VQ-LP0511HL?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Venco VQ-LP0511HL match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Venco VQ-LP0511HL percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Venco VQ-LP0511HL suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Venco VQ-LP0511HL for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 67 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 117.7 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Venco VQ-LP0511HL?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Venco VQ-LP0511HL.

### How many kWh per year does Venco VQ-LP0511HL add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Venco VQ-LP0511HL averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Venco VQ-LP0511HL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Venco VQ-LP0511HL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Venco VQ-LP0511HL?

Venco VQ-LP0511HL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Venco VQ-LP0511HL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Venco VQ-LP0511HL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Venco VQ-LP0511HL pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Venco VQ-LP0511HL easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Venco VQ-LP0511HL in a bathroom remodel?

Avoid specifying Venco VQ-LP0511HL in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Venco VQ-LP0511HL airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Venco VQ-LP0511HL achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Venco VQ-LP0511HL occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Venco VQ-LP0511HL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around Venco VQ-LP0511HL?

Use the related reference pages and estimators below to cross-check Venco VQ-LP0511HL against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Venco VQ-LP0511L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0511l/)
- [Venco VQ-LP0511L-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0511l-1/)
- [Venco VQ-AP0511WL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-ap0511wl-4667659/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)