---
title: "VENTECHLATION BPT13-12EN3 Bath Fan (50 CFM, 1.2 Sone)"
url: https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en3/
description: "ENERGY STAR specs for VENTECHLATION BPT13-12EN3: 50 CFM, 1.2 sones (#380 of 607), 3.7 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  VENTECHLATION BPT13-12EN3 Exhaust Fan Specifications

ENERGY STAR PD #4429500 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

Certified by EPA ENERGY STAR, VENTECHLATION BPT13-12EN3 delivers 50 CFM free-air (49.3 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 3.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 49 sq ft (8-ft height) or 43 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT13-12EN3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 49.3 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 98.6% @ 0.25"

- **Motor Draw**: 13.5 W (4.9 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VENTECHLATION BPT13-12EN3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.3 CFM out of 50 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: VENTECHLATION registers 12 certified models, with SKU BPT13-12EN3 (series: BPT) (PD #4429500) certified since 2025-06-06. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include Tech Drive TD-BF-17 (50.0 CFM) and Commercial Electric BPT13-12EN (50.0 CFM).

## How noisy is VENTECHLATION BPT13-12EN3 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while VENTECHLATION BPT13-12EN3 measures 1.2 sones across the 1,145-model registry.

## Why does rigid 3 in. diameter ducting protect VENTECHLATION BPT13-12EN3 airflow?

Connecting VENTECHLATION BPT13-12EN3 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify VENTECHLATION BPT13-12EN3 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for VENTECHLATION BPT13-12EN3 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT13-12EN3 / BPT | PD ID 4429500 (Qualified 2025-06-06) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (49.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit VENTECHLATION BPT13-12EN3?

Calculated coverage metrics translate VENTECHLATION BPT13-12EN3 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for VENTECHLATION BPT13-12EN3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 49 sq ft | 1 CFM/sq ft @ 49.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 43 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 118.3 kWh/yr (~$18.93/yr) | 13.5 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to VENTECHLATION BPT13-12EN3?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-17**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-17/) | 50 / 49.3 CFM | 1.2 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| [**Commercial Electric BPT13-12EN**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-12en/) | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| [**MaxLite EBF17-50-1-W**](https://siematic-charleston.com/ventilation-fans/maxlite-ebf17-50-1-w/) | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| [**Tech Drive FA-BF-01-L**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-01-l/) | 50 / 45.1 CFM | 1.0 sones (-0.20) | 3.8 CFM/W | 3 in. diameter |
| [**HomeWerks Worldwide 7140-50**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-50/) | 50 / 43.4 CFM | 1.0 sones (-0.20) | 3.0 CFM/W | 4 in. diameter |

## Does VENTECHLATION BPT13-12EN3 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check VENTECHLATION BPT13-12EN3 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install VENTECHLATION BPT13-12EN3 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VENTECHLATION BPT13-12EN3 for residential use.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Supplementary continuous trickle ventilation
- **Primary match:** Collar pairs with 3 in. diameter duct straight outdoors

## Which homeowner questions come up most for VENTECHLATION BPT13-12EN3?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around VENTECHLATION BPT13-12EN3.

### Why check VENTECHLATION BPT13-12EN3 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VENTECHLATION BPT13-12EN3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

### How does VENTECHLATION BPT13-12EN3 sound output compare to noisy contractor-grade fans?

Rated at 1.2 sones, VENTECHLATION BPT13-12EN3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define VENTECHLATION BPT13-12EN3?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can VENTECHLATION BPT13-12EN3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT13-12EN3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VENTECHLATION BPT13-12EN3?

VENTECHLATION BPT13-12EN3 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VENTECHLATION BPT13-12EN3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT13-12EN3's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does VENTECHLATION BPT13-12EN3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT13-12EN3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is VENTECHLATION BPT13-12EN3 undersized or poorly matched for a bath renovation?

Skip VENTECHLATION BPT13-12EN3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## Where can you explore more benchmarks around VENTECHLATION BPT13-12EN3?

Use the related reference pages and estimators below to cross-check VENTECHLATION BPT13-12EN3 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KORA SBF160DC-MS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/)
- [Air King AK110LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak110ls/)
- [VENTECHLATION BPT13-12EN-T Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-12en-t/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
