#  VENTECHLATION BPT14-24TG-H Exhaust Fan Specifications

ENERGY STAR PD #4480280 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Certified by EPA ENERGY STAR, VENTECHLATION BPT14-24TG-H delivers 110 CFM free-air (99 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 99 sq ft (8-ft height) or 88 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT14-24TG-H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 99 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 90.0% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VENTECHLATION BPT14-24TG-H vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside VENTECHLATION's 12-unit lineup, BPT14-24TG-H (series: BPT) carries PD #4480280 dating to 2025-07-25. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Tech Drive TD-BF-10 (110.0 CFM) and Tech Drive TD-BF-10-H (110.0 CFM).

## How noisy is VENTECHLATION BPT14-24TG-H compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while VENTECHLATION BPT14-24TG-H measures 1.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect VENTECHLATION BPT14-24TG-H airflow?

Connecting VENTECHLATION BPT14-24TG-H through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify VENTECHLATION BPT14-24TG-H performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for VENTECHLATION BPT14-24TG-H lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT14-24TG-H / BPT | PD ID 4480280 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit VENTECHLATION BPT14-24TG-H?

Calculated coverage metrics translate VENTECHLATION BPT14-24TG-H airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for VENTECHLATION BPT14-24TG-H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to VENTECHLATION BPT14-24TG-H?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-bl/) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(BN)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-bn/) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(WH)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-wh/) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |

## Does VENTECHLATION BPT14-24TG-H match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check VENTECHLATION BPT14-24TG-H percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install VENTECHLATION BPT14-24TG-H in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VENTECHLATION BPT14-24TG-H for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 49 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 99 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for VENTECHLATION BPT14-24TG-H?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around VENTECHLATION BPT14-24TG-H.

### When is VENTECHLATION BPT14-24TG-H undersized or poorly matched for a bath renovation?

Skip VENTECHLATION BPT14-24TG-H if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check VENTECHLATION BPT14-24TG-H CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VENTECHLATION BPT14-24TG-H registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does VENTECHLATION BPT14-24TG-H sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, VENTECHLATION BPT14-24TG-H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define VENTECHLATION BPT14-24TG-H?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can VENTECHLATION BPT14-24TG-H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT14-24TG-H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VENTECHLATION BPT14-24TG-H?

VENTECHLATION BPT14-24TG-H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VENTECHLATION BPT14-24TG-H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT14-24TG-H's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does VENTECHLATION BPT14-24TG-H satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT14-24TG-H clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Where can you explore more benchmarks around VENTECHLATION BPT14-24TG-H?

Use the related reference pages and estimators below to cross-check VENTECHLATION BPT14-24TG-H against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION BPT14-24TGHS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tghs/)
- [ACIQ AES100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aes100/)
- [Tech Drive TD-BF-25L-5CCT(BL) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-25l-5cct-bl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)