#  VENTECHLATION VF-BF-03 Exhaust Fan Specifications

ENERGY STAR PD #4697454 · Bathroom/Utility Room · Qualified 2026-09-02

Verified Specification Summary

Homeowners specifying VENTECHLATION VF-BF-03 gain 80 CFM at 0.1 in. w.g. (71.2 CFM at 0.25 in. w.g.) where it registers #107 of 607 in quietness (0.6 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 71 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION VF-BF-03 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 71.2 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 89.0% @ 0.25"

- **Motor Draw**: 17.8 W (6.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VENTECHLATION VF-BF-03 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.2 CFM out of 80 CFM (89.0% retention, 1.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms VENTECHLATION VF-BF-03 (series: VF) under PD #4697454 (12 models registered, 2026-09-02). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.8 watts, about 6.5 kWh/yr (~$1.04/yr at $0.16/kWh) for 1 hr/day shower timers or 155.9 kWh/yr (~$24.94/yr) continuously. Closest competing matches include Tech Drive TD-BF-04-plus (80.0 CFM) and AERO PURE ABF80L5OR (80.0 CFM).

## What acoustic percentile does VENTECHLATION VF-BF-03 occupy among 1,145 bath blowers?

Inspect how VENTECHLATION VF-BF-03 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits VENTECHLATION VF-BF-03 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around VENTECHLATION VF-BF-03 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do VENTECHLATION VF-BF-03 acoustic and static metrics stand?

Compare VENTECHLATION VF-BF-03 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VF-BF-03 / VF | PD ID 4697454 (Qualified 2026-09-02) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can VENTECHLATION VF-BF-03 handle taller ceilings or walk-in tub steam?

Evaluate how VENTECHLATION VF-BF-03 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for VENTECHLATION VF-BF-03

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.5 kWh/yr (~$1.04/yr) | 17.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 155.9 kWh/yr (~$24.94/yr) | 17.8 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near VENTECHLATION VF-BF-03?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-04-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-plus/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5OR**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SG**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sg/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SN**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sn/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5w/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |

## Is VENTECHLATION VF-BF-03 sized right for your shower or tub room?

Check whether VENTECHLATION VF-BF-03 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying VENTECHLATION VF-BF-03?

Match VENTECHLATION VF-BF-03 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 21 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 71.2 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for VENTECHLATION VF-BF-03?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to VENTECHLATION VF-BF-03.

### What happens to VENTECHLATION VF-BF-03 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, VENTECHLATION VF-BF-03 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does VENTECHLATION VF-BF-03 sit on acoustic comfort for senior homeowners?

Measuring 0.6 sones, VENTECHLATION VF-BF-03 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does VENTECHLATION VF-BF-03 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running VENTECHLATION VF-BF-03 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can VENTECHLATION VF-BF-03 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION VF-BF-03's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VENTECHLATION VF-BF-03?

VENTECHLATION VF-BF-03 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VENTECHLATION VF-BF-03's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION VF-BF-03's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can VENTECHLATION VF-BF-03 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION VF-BF-03 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does VENTECHLATION VF-BF-03 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with VENTECHLATION VF-BF-03.

## How can you cross-check VENTECHLATION VF-BF-03 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for VENTECHLATION VF-BF-03.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VENTECHLATION VF-BF-11L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-11l/)
- [Air King BFQ50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfq50/)
- [Tech Drive TD-BF-04-plus Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-plus/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)