#  Visper VF60110VS1 Exhaust Fan Specifications

ENERGY STAR PD #4510680 · Bathroom/Utility Room · Qualified 2025-08-22

Verified Specification Summary

The Visper VF60110VS1 (VisperSelect) moves 100 CFM at 0.1 in. w.g. (90.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 8.4 CFM/W efficacy, sizing bathrooms up to 90 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Visper VF60110VS1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 90.2 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.4 CFM/W (#317/1,145)

- **Static Retention**: 90.2% @ 0.25"

- **Motor Draw**: 11.9 W (4.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Visper VF60110VS1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Visper VF60110VS1 (EPA filing PD #4510680) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Visper's 1-unit lineup, VF60110VS1 (series: VisperSelect) carries PD #4510680 dating to 2025-08-22. Lighting kit: No. At 8.4 CFM/W (#317 of 1,145, top 27.9% of 1,145 rated models, more efficient than 72.1% of rated models, 3.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.9 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 104.2 kWh/yr (~$16.67/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta ITG100ELED (100.0 CFM).

## How does duct geometry alter Visper VF60110VS1 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Visper VF60110VS1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Visper VF60110VS1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Visper (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VF60110VS1 / VisperSelect | PD ID 4510680 (Qualified 2025-08-22) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (90.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Visper VF60110VS1 ventilate safely?

Sizing outputs below convert Visper VF60110VS1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Visper VF60110VS1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 104.2 kWh/yr (~$16.67/yr) | 11.9 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Visper VF60110VS1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Will Visper VF60110VS1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Visper VF60110VS1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Visper VF60110VS1?

Match Visper VF60110VS1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 40 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 90 sq ft with 8-ft ceilings (80 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Visper VF60110VS1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Visper VF60110VS1.

### Where does Visper VF60110VS1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Visper VF60110VS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Visper VF60110VS1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Visper VF60110VS1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Visper VF60110VS1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Visper VF60110VS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Visper VF60110VS1?

Visper VF60110VS1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Visper VF60110VS1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Visper VF60110VS1's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Visper VF60110VS1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Visper VF60110VS1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Visper VF60110VS1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Visper VF60110VS1.

### What happens to Visper VF60110VS1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Visper VF60110VS1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## Which guides and calculators connect next to Visper VF60110VS1?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Visper VF60110VS1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [VOTATEC VO-FN4W14-DC-3SPD Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w14-dc-3spd/)
- [Wintek BPT18C-TS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt18c-ts/)
- [Venco VQ-LP0810WL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/venco-vq-lp0810wl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)