---
title: "VOTATEC VO-FN4W14-DC-3SPD Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w14-dc-3spd/
description: "ENERGY STAR specs for VOTATEC VO-FN4W14-DC-3SPD: 100 CFM, 9.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  VOTATEC VO-FN4W14-DC-3SPD Exhaust Fan Specifications

ENERGY STAR PD #4439170 · Bathroom/Utility Room · Qualified 2025-05-23

Verified Specification Summary

In EPA dataset 8dv7-nngq, VOTATEC VO-FN4W14-DC-3SPD tests at 100 CFM free discharge (86.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 86 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W14-DC-3SPD Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 86.8 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.6 CFM/W (#206/1,145)

- **Static Retention**: 86.8% @ 0.25"

- **Motor Draw**: 10.4 W (3.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VOTATEC VO-FN4W14-DC-3SPD vs. 1,145-Model ENERGY STAR Benchmarks show?

VOTATEC VO-FN4W14-DC-3SPD (EPA filing PD #4439170) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.8 CFM out of 100 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside VOTATEC's 4-unit lineup, VO-FN4W14-DC-3SPD (series: VO-FN4W14-DC-3SPD) carries PD #4439170 dating to 2025-05-23. Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.4 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 91.1 kWh/yr (~$14.58/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## Why avoid unvented attic termination with VOTATEC VO-FN4W14-DC-3SPD?

Under ASHRAE 62.2 best practice, VOTATEC VO-FN4W14-DC-3SPD needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern VOTATEC VO-FN4W14-DC-3SPD?

Before cutting ceiling drywall or sizing attic transitions for VOTATEC VO-FN4W14-DC-3SPD, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VO-FN4W14-DC-3SPD / VO-FN4W14-DC-3SPD | PD ID 4439170 (Qualified 2025-05-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (86.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit VOTATEC VO-FN4W14-DC-3SPD?

Bathroom ventilation sizing below maps VOTATEC VO-FN4W14-DC-3SPD motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for VOTATEC VO-FN4W14-DC-3SPD

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 86 sq ft | 1 CFM/sq ft @ 86.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 77 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 36 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 91.1 kWh/yr (~$14.58/yr) | 10.4 W x 8,760 hrs / 1,000 |

## What peer models sit nearest VOTATEC VO-FN4W14-DC-3SPD in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to VOTATEC VO-FN4W14-DC-3SPD.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## What percentage of room demand does VOTATEC VO-FN4W14-DC-3SPD cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against VOTATEC VO-FN4W14-DC-3SPD tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install VOTATEC VO-FN4W14-DC-3SPD in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VOTATEC VO-FN4W14-DC-3SPD for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 86.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 86 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for VOTATEC VO-FN4W14-DC-3SPD?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing VOTATEC VO-FN4W14-DC-3SPD.

### How does VOTATEC VO-FN4W14-DC-3SPD sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, VOTATEC VO-FN4W14-DC-3SPD produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define VOTATEC VO-FN4W14-DC-3SPD?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can VOTATEC VO-FN4W14-DC-3SPD pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W14-DC-3SPD's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VOTATEC VO-FN4W14-DC-3SPD?

VOTATEC VO-FN4W14-DC-3SPD features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VOTATEC VO-FN4W14-DC-3SPD's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W14-DC-3SPD's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does VOTATEC VO-FN4W14-DC-3SPD satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W14-DC-3SPD clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is VOTATEC VO-FN4W14-DC-3SPD undersized or poorly matched for a bath renovation?

Skip VOTATEC VO-FN4W14-DC-3SPD if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check VOTATEC VO-FN4W14-DC-3SPD CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VOTATEC VO-FN4W14-DC-3SPD registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## What related resources expand on VOTATEC VO-FN4W14-DC-3SPD?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Wintek BPT18C-TS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt18c-ts/)
- [Dayton 3DPE7 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe7/)
- [Visper VF60110VS1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/visper-vf60110vs1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
