#  VOTATEC VO-FN4W25-AC-80 Exhaust Fan Specifications

ENERGY STAR PD #4439171 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

Homeowners specifying VOTATEC VO-FN4W25-AC-80 gain 80 CFM at 0.1 in. w.g. (66.3 CFM at 0.25 in. w.g.) where it registers #50 of 607 in quietness (0.4 sones) and delivers 3.5 CFM/W efficacy, venting bathrooms up to 66 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W25-AC-80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 66.3 CFM

- **Noise @ 0.1"**: 0.4 sones (#50/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 82.9% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VOTATEC VO-FN4W25-AC-80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 66.3 CFM at 0.25 in. w.g. (82.9% retention, 4.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms VOTATEC VO-FN4W25-AC-80 (series: VO-FN4W25-AC-80) under PD #4439171 (4 models registered, 2025-06-06). Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Wintek BPT15B-80H1 (80.0 CFM) and KORA SBF70N (76.5 CFM).

## What acoustic percentile does VOTATEC VO-FN4W25-AC-80 occupy among 1,145 bath blowers?

Inspect how VOTATEC VO-FN4W25-AC-80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits VOTATEC VO-FN4W25-AC-80 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around VOTATEC VO-FN4W25-AC-80 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do VOTATEC VO-FN4W25-AC-80 acoustic and static metrics stand?

Compare VOTATEC VO-FN4W25-AC-80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VO-FN4W25-AC-80 / VO-FN4W25-AC-80 | PD ID 4439171 (Qualified 2025-06-06) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (66.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can VOTATEC VO-FN4W25-AC-80 handle taller ceilings or walk-in tub steam?

Evaluate how VOTATEC VO-FN4W25-AC-80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for VOTATEC VO-FN4W25-AC-80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 66 sq ft | 1 CFM/sq ft @ 66.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near VOTATEC VO-FN4W25-AC-80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Wintek BPT15B-80H1**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h1/) | 80 / 66.3 CFM | 0.4 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**KORA SBF70N**](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/) | 76.5 / N/A CFM | 0.4 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Nektra 33003852**](https://siematic-charleston.com/ventilation-fans/nektra-33003852/) | 80 / 68.5 CFM | 0.3 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Wintek BPT15B-80H2**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/) | 80 / 68.5 CFM | 0.3 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Broan RB80**](https://siematic-charleston.com/ventilation-fans/broan-rb80/) | 80 / 63.1 CFM | 0.3 sones (-0.10) | 3.0 CFM/W | 4 in. diameter |

## Is VOTATEC VO-FN4W25-AC-80 sized right for your shower or tub room?

Check whether VOTATEC VO-FN4W25-AC-80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying VOTATEC VO-FN4W25-AC-80?

Match VOTATEC VO-FN4W25-AC-80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 66.3 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for VOTATEC VO-FN4W25-AC-80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to VOTATEC VO-FN4W25-AC-80.

### Where does VOTATEC VO-FN4W25-AC-80 sit on acoustic comfort for senior homeowners?

Measuring 0.4 sones, VOTATEC VO-FN4W25-AC-80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does VOTATEC VO-FN4W25-AC-80 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running VOTATEC VO-FN4W25-AC-80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can VOTATEC VO-FN4W25-AC-80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W25-AC-80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VOTATEC VO-FN4W25-AC-80?

VOTATEC VO-FN4W25-AC-80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VOTATEC VO-FN4W25-AC-80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W25-AC-80's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can VOTATEC VO-FN4W25-AC-80 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W25-AC-80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does VOTATEC VO-FN4W25-AC-80 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with VOTATEC VO-FN4W25-AC-80.

### What happens to VOTATEC VO-FN4W25-AC-80 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, VOTATEC VO-FN4W25-AC-80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## How can you cross-check VOTATEC VO-FN4W25-AC-80 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for VOTATEC VO-FN4W25-AC-80.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Wintek BPT15B-80H1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h1/)
- [KORA SBF70N Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/)
- [Broan QTXEG080X = QTXEGH with QTXEG080FX Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qtxeg080x-qtxegh-with-qtxeg080fx/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)