The VOTATEC VO-FN4W26-AC-100 (VO-FN4W26-AC-100) moves 100 CFM at 0.1 in. w.g. (85 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones), and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 85 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W26-AC-100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 85 CFM

- **Noise @ 0.1"**: 0.9 sones (#239/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 85.0% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does VOTATEC VO-FN4W26-AC-100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85 CFM out of 100 CFM (85.0% retention, 2.7 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms VOTATEC VO-FN4W26-AC-100 (series: VO-FN4W26-AC-100) under PD #4439172 (4 models registered, 2025-05-23). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Wintek BPT15B-100H1 (100.0 CFM) and Nektra 33003853 (100.0 CFM).

## Where does VOTATEC VO-FN4W26-AC-100 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.9 sones against all 1,145 EPA listings.

## How does duct geometry alter VOTATEC VO-FN4W26-AC-100 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to VOTATEC VO-FN4W26-AC-100?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for VOTATEC VO-FN4W26-AC-100 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | VO-FN4W26-AC-100 / VO-FN4W26-AC-100 | PD ID 4439172 (Qualified 2025-05-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (85 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.9 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can VOTATEC VO-FN4W26-AC-100 ventilate safely?

Sizing outputs below convert VOTATEC VO-FN4W26-AC-100 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for VOTATEC VO-FN4W26-AC-100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match VOTATEC VO-FN4W26-AC-100 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Wintek BPT15B-100H1**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h1/) | 100 / 85 CFM | 0.9 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Nektra 33003853**](https://siematic-charleston.com/ventilation-fans/nektra-33003853/) | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Nektra Pro 33003856**](https://siematic-charleston.com/ventilation-fans/nektra-pro-33003856/) | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Wintek BPT15B-100H2**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h2/) | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**S&P PC110XP**](https://siematic-charleston.com/ventilation-fans/s-p-pc110xp/) | 100 / 83.8 CFM | 0.9 sones (Same) | 3.6 CFM/W | 4 in. diameter |

## Will VOTATEC VO-FN4W26-AC-100 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether VOTATEC VO-FN4W26-AC-100 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip VOTATEC VO-FN4W26-AC-100 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for VOTATEC VO-FN4W26-AC-100 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 35 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 85 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern VOTATEC VO-FN4W26-AC-100?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting VOTATEC VO-FN4W26-AC-100.

### What duct and room conditions disqualify VOTATEC VO-FN4W26-AC-100?

Rule out VOTATEC VO-FN4W26-AC-100 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke VOTATEC VO-FN4W26-AC-100 capacity?

Because static drag at 0.25 in. w.g. lowers VOTATEC VO-FN4W26-AC-100 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is VOTATEC VO-FN4W26-AC-100 compared with a standard 3.0 sone builder fan?

Tested at 0.9 sones, VOTATEC VO-FN4W26-AC-100 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does VOTATEC VO-FN4W26-AC-100 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, VOTATEC VO-FN4W26-AC-100 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can VOTATEC VO-FN4W26-AC-100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W26-AC-100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing VOTATEC VO-FN4W26-AC-100?

VOTATEC VO-FN4W26-AC-100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change VOTATEC VO-FN4W26-AC-100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W26-AC-100's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does VOTATEC VO-FN4W26-AC-100 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W26-AC-100 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Which guides and calculators connect next to VOTATEC VO-FN4W26-AC-100?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for VOTATEC VO-FN4W26-AC-100.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Wintek BPT15B-100H1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h1/)
- [Wintek BPT15B-100H2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h2/)
- [S&P PC110XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pc110xp/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)